This command retrieves maximum number of timing sequences. This number represents
maximum index used in sequence commands.
Parameters:
<DNPD>
Integer value representing maximum sequence count
Remarks:
Overlapped command
Example:
TIM:PCO? Response: 64
[:SOURce]:TIMing:PRESet:NAME
Syntax:
[:SOURce]:TIMing:PRESet:NAME <SPD>
[:SOURce]:TIMing:PRESet:NAME?
Description:
This command allows reading and changing sequence name. Data will be saved to non-volatile
memory on TIM:PRES:SAVE command.
Parameters:
<SPD>
Quoted sequence name. Upper alpha, lower alpha, digits and spaces are
allowed. Maximum string size is 8 characters.
Remarks:
Overlapped command
Example:
TIM:PRES:NAME "TIME 1s"
TIM:PRES:NAME? Response: "TIME 1s"
[:SOURce]:TIMing:PRESet:PCLear
Syntax:
[:SOURce]:TIMing:PRESet:PCLear
Description:
This command clears existing sequence data including its timing table. Data will be saved to
non-volatile memory on TIM:PRES:SAVE command.
Parameters:
None
Remarks:
Overlapped command
Example:
TIM:PRES:PCL