Monitor Series PB# 4100031 Rev.B 09/11
PowerBoss, Inc. Copyright 2011
Page 59
SWEEP AND CYLINDRICAL SWEEP/SCRUB
COMPONENTS
Broom Door Flap Inspection
NOTE: Perform this inspection when the machine
is parked on a level surface.
1. Turn the machine off and lock the parking
brake.
2. Inspect broom door flaps for wear and damage.
Flap clearance should be ⅛” (3.18 mm) above
the floor.
3. Worn and damaged flaps should be replaced
immediately to maintain proper dust control.
Broom Door Flap Replacement and Adjustment
The flaps are attached to the broom doors by a
retainer bar, hex bolts and nuts. To remove the flaps,
remove the nuts, bolts and retainer bar. To adjust the
flaps, loosen the nuts and bolts, slide the flap up or
down as needed. Retighten the nuts and bolts.
PREVENTATIVE MAINTENANCE