PowerBoss, Inc. Copyright 2011
Monitor Series PB# 4100031 Rev.B 09/11
Page 58
Changing The Hydraulic Fluid
1. Turn off the engine and engage the parking
brake.
2. Place a drain pan on the floor below the
reservoir.
3. Remove the hose and fitting located on the
bottom rear of the reservoir and allow the fluid to
drain.
4. Discard the fluid in an approved manner, then
replace and reinstall the hose and fitting.
5. Remove the filler / breather cap located on
top of the reservoir and fill the reservoir with
approved hydraulic fluid.
NOTE: Ten (10) gallons (US) of fluid are required.
6. Check the dipstick to ensure the proper level is
achieved.
7. Install the filler / breather cap assembly.
8. Check the drain plug for leakage.
Changing The Hydraulic Fluid Filter
1. Turn off the engine and engage the parking
brake.
2. Unscrew the oil filter cartridge from the mount
and discard in an approved manner.
3. Apply a thin coating of fluid to the seal of a new
filter element.
4. Thread onto the mount and hand tighten.
5. Tighten an additional one-half turn beyond
hand tight.
NOTE: Do not over tighten.
6. Start the machine, shut it off, then check for
leakage.
PREVENTATIVE MAINTENANCE