Operation and installation manual
Page 46 of 82
(PVI-10.0/12.5-OUTD-xx Rev:1.2)
Message Error
Warning
Error
Type
Description
Int.Error // E019
Ileak
Sensor
fail
Leakage current error
Int.Error
//
E020
DcDc relay fail
DcDc relay fail
Int.Error
//
E021
Inverter relay fail
Inverter relay fail
Int.Error // E022
Autotest
Timeout
Int.Error // E023
Dc-Injection
Error
Grid OV
W004
//
Output Overvoltage
Grid UV
W005
//
Output Undervoltage
Grid OF
W006
//
Output Overfrequency
Grid UF
W007
//
Output Underfrequency
Z Grid HI
W008
//
Z grid out of range
Impedance out of range
Int.Error // E024
Unknown
Error
–
Internal Error
---------
//
E025
Riso Low (Log Only)
Low insulation leakage (log only)
Int.Error // E026
Vref
Error
Reference voltage error (VRef)
Int.Error // E027
Vgrid
Measures
Fault
Wrong grid voltage reading (VGrid)
Int.Error // E028
Fgrid
Measures
Fault
Wrong grid frequency reading (FGrid)
Int.Error // E029
Zgrid
Measures
Fault
Wrong grid impedance (ZGrid)
Int.Error // E030
Ileak
Measures
Fault
Wrong leak current reading (ILeak)
Int.Error // E031
Wrong
V
Measure
Wrong voltage reading V
Int.Error // E032
Wrong
I
Measure
Wrong current reading I
Fan Fail
W010
//
Fan Fail (No disconnection)
Fan failure (Log Only)
Int.Error // E033
UnderTemperature
Internal temperature
Содержание AURORA PVI-10.0/12.5-OUT-xx
Страница 38: ...Operation and installation manual Page 38 of 82 PVI 10 0 12 5 OUTD xx Rev 1 2 Fig 20 Data Transmission Options...
Страница 80: ...Operation and installation manual Page 80 of 82 PVI 10 0 12 5 OUTD xx Rev 1 2 CERTIFICATE OF CONFORMITY...
Страница 81: ...Operation and installation manual Page 81 of 82 PVI 10 0 12 5 OUTD xx Rev 1 2...
Страница 82: ...Operation and installation manual Page 82 of 82 PVI 10 0 12 5 OUTD xx Rev 1 2...