Operation and installation manual
Page 68 of 82
(PVI-10.0/12.5-OUTD-xx Rev:1.2)
6.2
Accuracy of measured values
Any measurement is subjected to error.
The charts below specify the following information for each measured item:
¾
unit of measurement;
¾
range;
¾
resolution.
Resolution
Name of
measured
variable
Unit of
measure
ment
Display Meas.
Max. error %
Input voltage PV
No.1
VP1 Vdc
1
V
250mV 2%
Input voltage PV
No.2
VP2 Vdc
1
V
250mV 2%
Input current PV
No.1
IP1 Adc
0.1
A
7mA 2%
Input current PV
No.2
IP2 Adc
0.1
A
7mA 2%
Power output PV
No.1
Pin1
W
1 W
6W
2%
Power output PV
No.2
Pin2
W
1 W
6W
2%
Output voltage
Vout
V
1 V
200mV
2%
Output current
Iout
A
0.1 A
20mA
2%
Output power
Pout
W
1 W
9W
2%
Frequency Freq
Hz
0.01
0,01
0.1%
Содержание AURORA PVI-10.0/12.5-OUT-xx
Страница 38: ...Operation and installation manual Page 38 of 82 PVI 10 0 12 5 OUTD xx Rev 1 2 Fig 20 Data Transmission Options...
Страница 80: ...Operation and installation manual Page 80 of 82 PVI 10 0 12 5 OUTD xx Rev 1 2 CERTIFICATE OF CONFORMITY...
Страница 81: ...Operation and installation manual Page 81 of 82 PVI 10 0 12 5 OUTD xx Rev 1 2...
Страница 82: ...Operation and installation manual Page 82 of 82 PVI 10 0 12 5 OUTD xx Rev 1 2...