SD700
–
PROFIBUS
POWER ELECTRONICS
24
TRIAL RUN
b)
Any of the MODBUS addresses configured in writing scenarios
is not within the valid MODBUS address range.
o
BIT 1 = Err. RD REG. NUMBER
Number of reading registers is not valid.
This BIT can be set for the following error conditions:
a)
The number of the registers configured for reading operation in
the read scenarios exceeds the limit specified by the
configuration type.
b)
Any of the MODBUS addresses configured in reading
scenarios is not within the valid MODBUS address range.
o
BIT 2 = Err. PARAM. LENGTH
Parameters length is not valid.
o
BIT 3 = Err. SCEN. NUMBER
Number of scenarios is not valid.
a)
The number of registers configured for reading operation in
reading scenarios exceeds the limit specified by the
configuration type.
b)
The number of the registers configured for writing operation in
writing scenarios exceeds the limit specified by the
configuration type.
c)
The number of valid MODBUS address-length pairs provided
with the parameter data exceeds the limit.
o
BIT 4 = Err. MODBUS DEVICE
This BIT is set if the drive fails responding over CAN interface.
o
BIT 5 = Err. CONFIG. FRAME
This BIT is set if the configuration data is not valid.
Содержание ProfiPower SD700 Type 1
Страница 1: ...Communication Network Profibus Communication...
Страница 2: ......
Страница 3: ...Communication Network Profibus Communication Edition April 2015 SD70BC03EI Rev E...
Страница 4: ...SD700 PROFIBUS POWER ELECTRONICS 2...
Страница 6: ...SD700 PROFIBUS POWER ELECTRONICS 4...
Страница 8: ...SD700 PROFIBUS POWER ELECTRONICS 6 INDEX...
Страница 14: ...SD700 PROFIBUS POWER ELECTRONICS 12 SAFETY INSTRUCTIONS...
Страница 45: ...www power electronics com...