SD700
–
PROFIBUS
POWER ELECTRONICS
22
TRIAL RUN
4.1.3.
Configuration
Configuration message indicates the size of the I/O transference
messages to the slave.
The modules that can be configured are the following ones:
ProfiPower SD700 Type 1
Specific module for Variable Speed Drive SD700.
5 output registers, 5 input registers.
ProfiPower SD700 Type 2
Specific module for Variable Speed Drive SD700.
60 output registers, 60 input registers.
ProfiPower SD700 Type 3
Pre-defined module for SD700 Series.
5 output registers, 2 input registers.
ProfiPower SD700 Type 4
Pre-defined module for SD700 Series.
27 output registers, 23 input registers.
ProfiPower SD700 Type 5
Specific module for Variable Speed Drive SD700.
10 output registers, 10 input registers.
The Profibus board reports the Profibus Master the possible errors
that can be produced in it. For that, it uses the frames of diagnosis
notification that can be visualized by any Profibus Master Software.
The errors that can be notified are the following ones: