MAINTENANCE
9.1
Error messages
Display
Description
UL
Measured value
< -20 % of the measuring range end value
(temperature)
OL
Exceeding of the detection area
(Flow rate > 120 % of the measuring range end value)
SC1
Flashing:
Short-circuit in output 1*
SC2
Flashing:
Short-circuit in output 2 *
SC
Flashing:
Short-circuit in both outputs *
Err
Flashing:
Error in the sensing element
* The relevant output is deactivated as long as the short-circuit continues.
NOTES
These messages are also displayed with deactivated display.
9.2
Sensor cleaning
A sensor cleaning must be conducted:
• Before every calibration / inspection (minimum once a year)
• Regularly during operation.
The sensor can be removed and cleaned.
9.2.1
Cleaning agent
For sensor cleaning, use tenside-containing (alkaline) agents or water-
soluble organic solvents (e.g. ethanol). For cleaning various conta-
minations, especially greases and oils, isopropanol is recommended.