10
Sensor output 1
• Switching signal as limit value for flow rate or flow speed, hysteresis or
window function as normally open or normally closed contact.
• Quantity control by preselection meter.
Sensor output 2
• Switching signal as limit value for flow rate, flow speed or temperature,
hysteresis or window function as normally open or normally closed contact.
• Analog signal (4...20 mA) for corresponding volume flow, flow speed or
temperature.
Relative measuring range (%)
Measuring range
Detection range / display range
0.33 % (0.4 %) - 100 %
0 % - 120 %
The absolute measuring range is depending on the nominal width (see
table below).
Absolute measuring range
WARNING
The compressed air meter may be used for volume flow measure-
ments of
operating compressed air up to an overpressure of
16 bar.
Nominal width
Measuring range
Detection /
display range
DN 15
0.33-100 m³/h
0-120 m³/h
DN 20
0.5-150 m³/h
0-180 m³/h
DN 25
0.8-250 m³/h
0-300 m³/h
DN 32
1.3-400 m³/h
0-480 m³/h
DN 40
2.1-620 m³/h
0-744 m³/h
DN 50
3.3-1000 m³/h
0-1200 m³/h
Data according to DIN ISO 2533 (15 °C, 1013 mbar and 0 % rel. humidity).