20
5.8
Electrical connections
Disconnect the voltage supply before making the connections.
WARNING
The device may
exclusively be installed by a trained electrician
.
Follow the national and international regulations for the instal-
lation of electrical systems. The voltage supply system shall be
designed according to EN50178, SELV, PELV. In order to meet the
“limited voltage” requirements according to UL 508, the device
must be fed from a galvanically isolated source and equipped with
an overcurrent facility.
NOTES
If you connect the sensor directly or use a
4-core connection line,
proceed according to 5.8.1.
If you use the optionally available
5-core connecting cable
with
potential-free impulse output (
4.2.2 | p. 14)
proceed according
to 5.8.2 for the connection of the sensor.
5.8.1
4-core pin assignment
If you do not use the optionally available connecting line for potential
isolation, the following line assignment applies to the connecting line or
plug assignment directly on the sensor.
4
1
3
2
OUT2/InD
L+
L
BN
BU
OUT1/IO-Link
WH
BK
4
3
1
2
Pin No.
Core colour
Assignment
1
Brown
+L (19…30 V DC)
2
White
OUT2
3
Blue
0 V DC (GND)
4
Black
OUT1