ACS CANopen Manual
Version 20110928
10 of 44
AC C E L E N S ( AC S ) C AN o p e n
3 . I n s t al l at i o n
3.1 Accessories
* The documentation and the EDS file can also be downloaded from our website
http://www.posital.sg/
3.2 Pin Assignement
The inclinometer is connected via a 5-pin round M12 connector.
(Standard M12, Male side at sensor, Female at connector counterpart
Or connection cable).
Pin Assignment
3.3 Installation Precautions
WARNING
Do not remove or mount while the inclinometer is under power!
Do not stand on the inclinometer!
Avoid mechanical load!
Article No
Article
Description
ACS360/080
Inclinometer
ACS series of Inclinometers (Industrial / Heavy-Duty)
Download
Datasheet*
ACS Datasheet, specifications and drawings
Download
User Manual*
Installation and Configuration User Manual (English)
Download
EDS-File*
Electronic Datasheet (EDS) file for configuration
10001978
PAM5
Female M12, 5pin A-coded connector, with 2m PUR shielded cable
10012182
PAM5 2m
Female M12, 5pin A-coded connector, with 5m PUR shielded cable
10005631
Terminal Resistor
External terminal resistors for higher baud rate transmissions
Signal
5 pin round connector pin number
CAN Ground
1
V
S
Supply Voltage
2
0 V Supply Voltage
3
CAN High
4
CAN Low
5