Instruction Manual
w
PE 100-T
27
4.5.
TROUBLE-SHOOTING
Trouble
Cause
Remedy
Drive motor (electric)
Motor will not start
Electric circuitry faulty
Check all fuses, terminal connections,
wire leads, make sure that motor data
complies with mains supply
Motor/engine runs eccentrically
V-belt worn
Replace
Motor protection switch is switching
off the unit
Wrong adjustment of the motor pro
tection switch
Set to nominal motor current. Observe
temperature compensation (+20
°
C
=1,0)
For ambient temperature
+ 10
°
C : correction factor 0,94
+ 30
°
C : correction factor 1,05
+ 40
°
C : correction factor 1,12
Unsufficient voltage because of weak
power supply
Switch off other consuming devices
Motor protection switch is switching
off the unit
Power supply cable to long or to thin
Use suitable cable
Drive motor (petrol)
Motor will not start
See motor instructions
See motor instructions
Motor runs eccentrically
V-belt worn
Motor stops
Low oil level
Top up oil
Drive system
Excessive v-belt wear (black deposits
on belt guard)
V-belt tension
Re-tighten, see chapter 4.4.10.
Pulleys not aligned
Re-adjust, see chapter 4.4.10.
Compressor
Compressor does not attain final pres
sure
Condensate drain valve(s) leaking
Tighten and reseal
Final pressure safety valve defective
(blows too soon)
Replace safety valve
No cartridge in filter system P11 (air
escaping through cartridge safety
bore)
Replace cartridge, see chapter 4.4.4.
Vent screw for final pressure safety
valve not in operating position
To vent, unscrew until completely
open, see chapter 4.4.7.
Air delivery drops
Intake filter soiled
Clean or replace filter cartridge, see
chapter 4.4.2.
Pipe coupling leaking
Retighten couplings
Excessive wear of 3rd stage piston
Replace piston and sleeve of 3rd stage
Intermediate pressure safety valve
blows
Intermediate pressure too high be
cause of defective inlet or pressure
valve of the following stage
Check/replace inlet or pressure valve,
see chapter 4.4.9.
Safety valve leaking
Replace safety valve
Compressor overheats
Insufficient cooling air
Check location; ensure proper cooling
air flow, see chapter 3.1.
Ambient temperature too high
Check location; ambient temperature
max. +45
°
C (113
°
F), see chapter
Direction of rotation is wrong
Correct direction of rotation
Inlet and pressure valve of one stage is
leaking
Check valves, clean/replace if neces
sary, see chapter 4.4.9.
Taste of oil in the air
TRIPLEX cartridge saturated
Replace cartridge, see chapter 4.4.4.
Unqualified lubricant being used
Replace oil with an approved brand,
see Lubricating oil list in annex.
Содержание PE 100-T
Страница 1: ...High Pressure Breathing Air Compressors Instruction manual...
Страница 2: ......
Страница 6: ...Instruction Manual w PE 100 T iv NOTES Model Serial No Date of purchase Dealer address phone no...
Страница 39: ...Instruction Manual w PE 100 T 33...
Страница 40: ......
Страница 41: ...Instruction Manual w PE 100 T 35 8 ANNEX Schematic diagram Lubricating oil list Parts list...
Страница 42: ...Instruction Manual w PE 100 T 36...
Страница 44: ...Instruction Manual w PE 100 T 38...