Work on electrical equipment must only be carried out by qualified electricians.
Hydraulic lines
After the first hour of operation, check that all hydraulic connections are secure and are not
leaking.
Check that all hydraulic connections are secure and are not leaking after every further 100
operating hours.
▪ Damaged hydraulic lines must be replaced immediately.
Saw blade
Check that the saw blade is firmly seated before each use.
Check the saw blade for wear and damage before each use. Sharpen or replace it if
necessary.
V-belt tension
The V-belts must be tensioned so that they deflect about 8 mm in the middle when thumb
pressure is applied.
▪ See ..... Changing the V-belt [➙ 41]
Oil level
To check the oil level place the machine on an even surface.
Hydraulic oil level
When the oil sight glass is filled above halfway, the oil level is at its maximum.
When the oil level is towards the bottom of the oil sight glass, the oil level its at its minimum.
1
2
3
1
Vent screw
3
Oil sight glass
2
Oil drain screw
If this is the case, the hydraulic oil must be topped up immediately.
▪ See: Changing the hydraulic oil [➙ 43]
The oil filter only needs to be checked when the oil is changed.
8.4
8.5
8.6
8.7
8.7.1
Checks
36