background image

  

5

PART 1 – INSTRUCTION MANUAL

Congratulations on buying a portable Victoria SPA!

SPA Victoria allows you to appreciate the ad-
vantages of hydromassage for four people 
sitting places) both outside a building and in-
side a large bathroom.

The bath is equipped with an ozonator which 
makes it easier to keep the water clean and is 
very effective in beauty treatment. The qualities 
of ozone are described in detail in Part 1.8.

Thanks to the „antifrost system”, it is even po-
ssible to take a bath when the outside tempe-
rature below freezing point. The detailed des-
cription of the system is provided in Part 1.1.

The SPA Victoria comprises:

- electronic control panel with a display
- 2 hydromassage aeration regulators
- 2 kW electric heater, with water temperature control function (6 kW as option with supply 3~400 V)
- 2,0 HP (1.5 kW) hydromassage pump 
- 1.2 W axial blower
- water ozonator
- “anti-frost” system – for outside temperatures below freezing point
- water temperature sensor
- hydromassage:
 • 

fi xed mini jets - 16 pcs

 • 

fi xed ozone mini jet - 1 pcs

 

• 4” adjustable rotating stream jets - 4 pcs

 

• 4” pulsating stream jets - 2 pcs

 

• 4” multi-massage jets - 2 pcs

 

• air channels ( 95 openings)

- water suction point
- underwater halogen lighting
- fi ltration system with replaceable inserts
- water treatment unit
- timber steps (mahogany or pine wood - additional option).
- wooden housing (mahogany or pine wood, as an additional option)
- thermal cover (optional)

Switching off the electrical supply by using test button of the differential-current 
switch after the bath is emptied is recommended, in order to avoid operation of 
the hydro-massage pump without water in the bath.

Содержание VICTORIA SPA

Страница 1: ...SPA Bath VICTORIA SPA 178 Installation and user manual...

Страница 2: ...roducts for many years The endurance reliability and safety of our baths has always been of greatest importance to us that is why we always use materials and devi ces from reputable suppliers The manu...

Страница 3: ...hermal cover additional optional 15 1 11 Measurement and treatment formula set 15 PART 2 INSTALLATION MANUAL 2 1 Transport 17 2 2 Site preparation 17 2 3 Bath positioning 17 2 4 Assembly disassembly o...

Страница 4: ...rsons suffering from heart disorder diseases or high blood pressure need to consider special conditions created inside the SPA baths and consult their physician before using such baths We recommend us...

Страница 5: ...tors 2 kW electric heater with water temperature control function 6 kW as option with supply 3 400 V 2 0 HP 1 5 kW hydromassage pump 1 2 W axial blower water ozonator anti frost system for outside tem...

Страница 6: ...tant task of SPA electronic system is holding temperature of water within the range bet ween 15 to 400 C However electronic system has additional feature winter operation mode Anti frost Smart Winter...

Страница 7: ...f the polis hing process Metallic elements have been coated with silicone oil for protection purposes The SPA should be washed off e g with a dishwashing detergent prior to lling the bath with water 1...

Страница 8: ...pump over to a low gear ltration this icon 1 blinks on the display Pressing the button once again switches the pump over to a top gear massage this icon 1 appears on the display Pressing the same but...

Страница 9: ...The economy mode can be activated the icon is displayed permanently or suspended for 40 minutes from the moment of switching off the last pump when at least one pump is switched on during this mode Re...

Страница 10: ...nutes along with the ozonator The heater works normally during the fast ltration process After switching this function on the boo sign ap pears on the display and is present until this function is nis...

Страница 11: ...y shaped icon blinks The LocP sign will appear on the display after pressing this button on the control panel for 3 seconds Once this sign has appeared the function becomes active and the key icon is...

Страница 12: ...egulation of massage intensity water suction point The water massage intensity regulation is possible by means of aeration regulators located at the perimeter of the bath top by adding air to the wate...

Страница 13: ...plant Ozone de nitely supports maintenance hygiene in the SPA The heated and ozonized air is pumped into the air duct system underneath the bath Operating only during ltration Fig 1 5 Ozone producing...

Страница 14: ...e element D and subsequently element E 4 clean or replace lter inserts D and E 5 install new lters in the opposite order i e E and D 6 Install elements C and B 7 cleaning relies on rinsing of the inse...

Страница 15: ...om sun light heat 1 11 Measurement and treatment formula set Before the first bath and depending on how frequently the SPA Victoria bath is used please check the water pH with the enclosed Dinofresh p...

Страница 16: ...irectly after the correction Do not add the granules any where close to the skimmer 2 Dinofresh active oxygen granules for water disinfection to be added to the skimmer Dosage 25g 1000 litres is a sta...

Страница 17: ...ption is 5kW and requires use of a 3x2 5 mm2 electrical cable as the connection with regard to the safety of the users in all cases the supply cable must be protected by means of a differential curren...

Страница 18: ...of the general electrical installation in the house The electrical connection line needs to be first of all pro tected with a 40A safety fuse and then connected to an au tomatic differential current s...

Страница 19: ...cable must be connected to the xed power supply to an IP X5 safety level Socket in stallation is not permitted The power installation in the wall can be connected by a junction box An IP X5 junction...

Страница 20: ...eping the bath clean should not be a problem Mechanically damaged gloss acrylic small shallow scratches can be easily repaired In the case of small scratches a small amount of wax free car polish sho...

Страница 21: ...EL VAR PUMP VAR BLOWER SD INTERFACE TSC 9 KEYPAD MAIN KEYPAD LEVEL SENSE I2C BUS ASTREL HI LI PROBE BLOWER OZONE L N PE Multicolor LED LAMP OZONE GENERATOR 230V 50 60Hz MASSAGE PUMP 1 1 5 kW MAINS SUP...

Страница 22: ...INTERFACE TSC 9 KEYPAD MAIN KEYPAD LEVEL SENSE I2C BUS ASTREL HI LI PROBE BLOWER OZONE L N PE L N PE R91 R90 R89 R88 R120 R119 R118 R94 INPUT VOLTAGE PUMP 2 L LO N PE PUMP 2 L HI N PE PUMP 1 L LO N P...

Страница 23: ...s post warranty payable service 4 The warranty will not be valid in these cases a a fault or faulty operation resulting from anomalies or non compliance with the product speci c instala tion rules or...

Страница 24: ...24 Notes...

Страница 25: ...25 Notes...

Страница 26: ...26 Notes...

Страница 27: ...TINGS FACTORY NUMBER DATE OF PRODUCTION AND TESTING TECHNICAL PRODUCT SHEET NOMINAL POWER REQUIREMENTS FUSING REQUIREMENTS VOLTAGE FREQUENCY 230V 50 Hz F Victoria SPA 25 A 5 kW THERMAL PROTECTION QUAL...

Страница 28: ...w poolspa pl 25 03 2009 PI3000130 POOL SPA company has the policy of constant improvement of products and reserves the right to introduce changes to the speci cation and colours without a prior noti c...

Отзывы: