background image

10

  

water pump work at the highest speed, while the heater is on. When one pump works in a low gear 
along with the water ozonator and the electric heater. The duration of fi ltration depends on the time 

setting. Filtration mode is indicated by this special icon 

 on the display. Filtration process can be 

suspended (the fi ltration icon is blinking on the display) by switching on any of massage pumps. 
Filtration will return to its normal mode after 40 minutes after user last operations. Switching the 
lighting on does not suspend the fi ltration process.

Setting fi ltration parameters:

 Press the fi ltration button 

 The display will show 

Fdxx

, where 

xx

 stands for the fi ltration duration from 0 to 12 hours. 

 If 

xx

 is set on 0, the fi ltration does not work

 Filtration duration can be changed with these arrows 

 

 and the selected value is confi r-

med by pressing the fi ltration button 

 The blinking fi ltration start time will appear on the display

 Changes are made with these arrows 

 

 and confi rmed by using the fi ltration button 

 After confi rming the selected minutes by pressing the fi ltration button, the controller memorizes 

the setting and returns to its normal work. If no button is pressed for longer than 5 seconds during 
the setting procedure, the controller will quit the fi ltration setting menu and will not remember any 
changes.

1.5.7. Fast fi ltration (Boost) 

The “boo” function enables to make faster water fi ltration. During this function, all the pumps work for 
1 minute. Additionally, pump works in a fast gear for 45 minutes along with the ozonator. The heater 
works normally during the fast fi ltration process. After switching this function on, the „boo” sign ap-
pears on the display and is present until this function is fi nished. Fast fi ltration process is triggered 
by pressing and holding the pump 1 button for 10 seconds. This function can be switched off earlier 
by starting any other pumps.

1.5.8. Setting the water temperature

To set the water temperature, press the arrow buttons 

 

 on the control panel.

The selected temperature does not have to be confi rmed, but only set. The display, after 5 seconds 
from the last pressing, will return to the previous status and start showing the current water tempera-
ture. The controller maintains the set temperature with an accuracy of ± 0,5°C (1°F). If the water 
temperature is lower than that previously set, the controller will start the heater and low gear pump 
(fi ltration circuit) and keep it on until the water reaches its required temperature. If the economy mode 

is on 

 the controller keeps the water temperature lower by 10 degrees than that previously set. 

After the economy mode is off, the controller returns to maintaining the previou set temperature. 

1.5.9. Increasing the maximum temperature

This function allows the user to increase the water temperature by two degrees centigrade above 
40°C (104°F). To set the temperature above 40°C, set the maximum temperature and next press 

and hold the up arrow button 

 for 5 seconds until the 

Orx.x

 sign appears on the display, where

x.x signifi es how much the temperature value is to be increased above the maximum temperature. 
This value can be increased half a degree, and the maximum value is two grades, so the maximum water 

Содержание VICTORIA SPA

Страница 1: ...SPA Bath VICTORIA SPA 178 Installation and user manual...

Страница 2: ...roducts for many years The endurance reliability and safety of our baths has always been of greatest importance to us that is why we always use materials and devi ces from reputable suppliers The manu...

Страница 3: ...hermal cover additional optional 15 1 11 Measurement and treatment formula set 15 PART 2 INSTALLATION MANUAL 2 1 Transport 17 2 2 Site preparation 17 2 3 Bath positioning 17 2 4 Assembly disassembly o...

Страница 4: ...rsons suffering from heart disorder diseases or high blood pressure need to consider special conditions created inside the SPA baths and consult their physician before using such baths We recommend us...

Страница 5: ...tors 2 kW electric heater with water temperature control function 6 kW as option with supply 3 400 V 2 0 HP 1 5 kW hydromassage pump 1 2 W axial blower water ozonator anti frost system for outside tem...

Страница 6: ...tant task of SPA electronic system is holding temperature of water within the range bet ween 15 to 400 C However electronic system has additional feature winter operation mode Anti frost Smart Winter...

Страница 7: ...f the polis hing process Metallic elements have been coated with silicone oil for protection purposes The SPA should be washed off e g with a dishwashing detergent prior to lling the bath with water 1...

Страница 8: ...pump over to a low gear ltration this icon 1 blinks on the display Pressing the button once again switches the pump over to a top gear massage this icon 1 appears on the display Pressing the same but...

Страница 9: ...The economy mode can be activated the icon is displayed permanently or suspended for 40 minutes from the moment of switching off the last pump when at least one pump is switched on during this mode Re...

Страница 10: ...nutes along with the ozonator The heater works normally during the fast ltration process After switching this function on the boo sign ap pears on the display and is present until this function is nis...

Страница 11: ...y shaped icon blinks The LocP sign will appear on the display after pressing this button on the control panel for 3 seconds Once this sign has appeared the function becomes active and the key icon is...

Страница 12: ...egulation of massage intensity water suction point The water massage intensity regulation is possible by means of aeration regulators located at the perimeter of the bath top by adding air to the wate...

Страница 13: ...plant Ozone de nitely supports maintenance hygiene in the SPA The heated and ozonized air is pumped into the air duct system underneath the bath Operating only during ltration Fig 1 5 Ozone producing...

Страница 14: ...e element D and subsequently element E 4 clean or replace lter inserts D and E 5 install new lters in the opposite order i e E and D 6 Install elements C and B 7 cleaning relies on rinsing of the inse...

Страница 15: ...om sun light heat 1 11 Measurement and treatment formula set Before the first bath and depending on how frequently the SPA Victoria bath is used please check the water pH with the enclosed Dinofresh p...

Страница 16: ...irectly after the correction Do not add the granules any where close to the skimmer 2 Dinofresh active oxygen granules for water disinfection to be added to the skimmer Dosage 25g 1000 litres is a sta...

Страница 17: ...ption is 5kW and requires use of a 3x2 5 mm2 electrical cable as the connection with regard to the safety of the users in all cases the supply cable must be protected by means of a differential curren...

Страница 18: ...of the general electrical installation in the house The electrical connection line needs to be first of all pro tected with a 40A safety fuse and then connected to an au tomatic differential current s...

Страница 19: ...cable must be connected to the xed power supply to an IP X5 safety level Socket in stallation is not permitted The power installation in the wall can be connected by a junction box An IP X5 junction...

Страница 20: ...eping the bath clean should not be a problem Mechanically damaged gloss acrylic small shallow scratches can be easily repaired In the case of small scratches a small amount of wax free car polish sho...

Страница 21: ...EL VAR PUMP VAR BLOWER SD INTERFACE TSC 9 KEYPAD MAIN KEYPAD LEVEL SENSE I2C BUS ASTREL HI LI PROBE BLOWER OZONE L N PE Multicolor LED LAMP OZONE GENERATOR 230V 50 60Hz MASSAGE PUMP 1 1 5 kW MAINS SUP...

Страница 22: ...INTERFACE TSC 9 KEYPAD MAIN KEYPAD LEVEL SENSE I2C BUS ASTREL HI LI PROBE BLOWER OZONE L N PE L N PE R91 R90 R89 R88 R120 R119 R118 R94 INPUT VOLTAGE PUMP 2 L LO N PE PUMP 2 L HI N PE PUMP 1 L LO N P...

Страница 23: ...s post warranty payable service 4 The warranty will not be valid in these cases a a fault or faulty operation resulting from anomalies or non compliance with the product speci c instala tion rules or...

Страница 24: ...24 Notes...

Страница 25: ...25 Notes...

Страница 26: ...26 Notes...

Страница 27: ...TINGS FACTORY NUMBER DATE OF PRODUCTION AND TESTING TECHNICAL PRODUCT SHEET NOMINAL POWER REQUIREMENTS FUSING REQUIREMENTS VOLTAGE FREQUENCY 230V 50 Hz F Victoria SPA 25 A 5 kW THERMAL PROTECTION QUAL...

Страница 28: ...w poolspa pl 25 03 2009 PI3000130 POOL SPA company has the policy of constant improvement of products and reserves the right to introduce changes to the speci cation and colours without a prior noti c...

Отзывы: