1.4. Ventilation

High water temperature during bathing in the bath (up to 40°C) causes emitting of big amounts of 
steam. An effi cient ventilation system should be provided in the room with the bath. Installing of a 
steam condenser in the room which will maintain constant air humidity will minimize the risk of dam-
pening of walls and ceiling. An air-conditioning system in the building allows for elimination of the 
steam condenser. Such problem does not exist in case of a bath operating in open air conditions.

1.5. Main functions accessible from the electronic control panel.

Victoria SPA control panel

1.5.1. Switching on/off the pump 

 

The hydromassage pump can be switched on/off directly from the electronic control panel. After 

starting the pump, this icon 

1

, appears on the display and after switching it off, the icon disap-

pears.
With the two-gear pump, pressing the button for the fi rst time switches the pump over to a low gear 

(fi ltration; this icon 

1

 blinks on the display). Pressing the button once again switches the pump over 

to a top gear (massage; this icon 

1

 appears on the display). Pressing the same button again swit-

ches the pump off and the icon disappears from the display.
In some cases, the pump automatically switches over to a low gear after connecting it to the power 
supply. This happens during the 

fi ltration

 or the water 

heating process

 in the SPA bath.

The pump working in massage mode have automatic time out (20 minutes) from the last button 
start.

 

 - unavailable

1.5.2. Extra equipment 

 - airmassage (on/off)

1.5.3. Switching on/off the lighting 

Press the button with the lamp symbol on it to switch on the lighting. This icon 

 appears on the 

display. Press the same button again to switch off the lighting, and the icon disappears from the 
display. The lighting switches off automatically after 2 hours from the last pressing of the lighting 
on/off button.

Press and hold this button 

 for more than 5 seconds to view from inside the spa the water tem-

perature and time display projection, to read these data.

Содержание VICTORIA SPA

Страница 1: ...SPA Bath VICTORIA SPA 178 Installation and user manual...

Страница 2: ...roducts for many years The endurance reliability and safety of our baths has always been of greatest importance to us that is why we always use materials and devi ces from reputable suppliers The manu...

Страница 3: ...hermal cover additional optional 15 1 11 Measurement and treatment formula set 15 PART 2 INSTALLATION MANUAL 2 1 Transport 17 2 2 Site preparation 17 2 3 Bath positioning 17 2 4 Assembly disassembly o...

Страница 4: ...rsons suffering from heart disorder diseases or high blood pressure need to consider special conditions created inside the SPA baths and consult their physician before using such baths We recommend us...

Страница 5: ...tors 2 kW electric heater with water temperature control function 6 kW as option with supply 3 400 V 2 0 HP 1 5 kW hydromassage pump 1 2 W axial blower water ozonator anti frost system for outside tem...

Страница 6: ...tant task of SPA electronic system is holding temperature of water within the range bet ween 15 to 400 C However electronic system has additional feature winter operation mode Anti frost Smart Winter...

Страница 7: ...f the polis hing process Metallic elements have been coated with silicone oil for protection purposes The SPA should be washed off e g with a dishwashing detergent prior to lling the bath with water 1...

Страница 8: ...pump over to a low gear ltration this icon 1 blinks on the display Pressing the button once again switches the pump over to a top gear massage this icon 1 appears on the display Pressing the same but...

Страница 9: ...The economy mode can be activated the icon is displayed permanently or suspended for 40 minutes from the moment of switching off the last pump when at least one pump is switched on during this mode Re...

Страница 10: ...nutes along with the ozonator The heater works normally during the fast ltration process After switching this function on the boo sign ap pears on the display and is present until this function is nis...

Страница 11: ...y shaped icon blinks The LocP sign will appear on the display after pressing this button on the control panel for 3 seconds Once this sign has appeared the function becomes active and the key icon is...

Страница 12: ...egulation of massage intensity water suction point The water massage intensity regulation is possible by means of aeration regulators located at the perimeter of the bath top by adding air to the wate...

Страница 13: ...plant Ozone de nitely supports maintenance hygiene in the SPA The heated and ozonized air is pumped into the air duct system underneath the bath Operating only during ltration Fig 1 5 Ozone producing...

Страница 14: ...e element D and subsequently element E 4 clean or replace lter inserts D and E 5 install new lters in the opposite order i e E and D 6 Install elements C and B 7 cleaning relies on rinsing of the inse...

Страница 15: ...om sun light heat 1 11 Measurement and treatment formula set Before the first bath and depending on how frequently the SPA Victoria bath is used please check the water pH with the enclosed Dinofresh p...

Страница 16: ...irectly after the correction Do not add the granules any where close to the skimmer 2 Dinofresh active oxygen granules for water disinfection to be added to the skimmer Dosage 25g 1000 litres is a sta...

Страница 17: ...ption is 5kW and requires use of a 3x2 5 mm2 electrical cable as the connection with regard to the safety of the users in all cases the supply cable must be protected by means of a differential curren...

Страница 18: ...of the general electrical installation in the house The electrical connection line needs to be first of all pro tected with a 40A safety fuse and then connected to an au tomatic differential current s...

Страница 19: ...cable must be connected to the xed power supply to an IP X5 safety level Socket in stallation is not permitted The power installation in the wall can be connected by a junction box An IP X5 junction...

Страница 20: ...eping the bath clean should not be a problem Mechanically damaged gloss acrylic small shallow scratches can be easily repaired In the case of small scratches a small amount of wax free car polish sho...

Страница 21: ...EL VAR PUMP VAR BLOWER SD INTERFACE TSC 9 KEYPAD MAIN KEYPAD LEVEL SENSE I2C BUS ASTREL HI LI PROBE BLOWER OZONE L N PE Multicolor LED LAMP OZONE GENERATOR 230V 50 60Hz MASSAGE PUMP 1 1 5 kW MAINS SUP...

Страница 22: ...INTERFACE TSC 9 KEYPAD MAIN KEYPAD LEVEL SENSE I2C BUS ASTREL HI LI PROBE BLOWER OZONE L N PE L N PE R91 R90 R89 R88 R120 R119 R118 R94 INPUT VOLTAGE PUMP 2 L LO N PE PUMP 2 L HI N PE PUMP 1 L LO N P...

Страница 23: ...s post warranty payable service 4 The warranty will not be valid in these cases a a fault or faulty operation resulting from anomalies or non compliance with the product speci c instala tion rules or...

Страница 24: ...24 Notes...

Страница 25: ...25 Notes...

Страница 26: ...26 Notes...

Страница 27: ...TINGS FACTORY NUMBER DATE OF PRODUCTION AND TESTING TECHNICAL PRODUCT SHEET NOMINAL POWER REQUIREMENTS FUSING REQUIREMENTS VOLTAGE FREQUENCY 230V 50 Hz F Victoria SPA 25 A 5 kW THERMAL PROTECTION QUAL...

Страница 28: ...w poolspa pl 25 03 2009 PI3000130 POOL SPA company has the policy of constant improvement of products and reserves the right to introduce changes to the speci cation and colours without a prior noti c...

Отзывы: