The V-Series endpoints now functions by caching all of the Global Directory listings.  
Because of this change in functionality, an end user may experience the following:

 

 

Changes made to the Global Directory will take 10 minutes to be reflected in the V-
Series Global Address Book.

 

 

The V-Series endpoints will take up to 10 minutes when registering with the Global 
Directory.

 

 

If the password on the Global Directory has been changed and the password entered 
on a V-Series endpoint (version 5.X) was not updated to the new password, old 
cached Global Address entries will still be shown.  Rebooting the endpoint clears the 
cache and updates the V-Series Global Directory password.

 

5. 

Software Update – 

 

The iPower does not update Global Management System that the software update was 
successful. Therefore, after completing a software update for an iPower, Global 
Management System will show as failed for the iPower’s software update status even 
though it may have been successful.

 

If the software update file requires a key file, the key file must not have any spaces in the 
name of key file, or you will see a network error message.

 

Page cannot be displayed” message when trying to upload an iPower.exe in Softupdate 

configuration in Windows 2003.  To enable softupdate for iPower on Windows 2003:  

 

Start Control Panels Administrative Tools Internet Information Services (IIS) 
Manager.   In the left-hand panel, expand the branch with your server's name, 
and click "Web Service Extensions."  

 

From the "Action" menu, click "Add a new Web Service Extension" to open the 
"New Web Service Extension" window.  In the "Extension Name" field, type 
"iPower SoftUpdate"  

 

Click "Add.”  Browse to the SWUpload.dll file located within the Global 
Management System installation directory:

 

C:\Program Files\Polycom\pwx\WebApp\isapi\SWUpload.dll.  

 

Click "Open" to select the file.  Click "OK" in the "Add File" window.  

 

Click "Set extension status to Allowed" so that the changes are enabled.  

 

Click "OK" in the "New Web Service Extension" window to save your changes. 

 

6. 

Provisioning 

– 

 

In VSX 7000 version 5.1.1, the following fields cannot be provisioned: admin password, 
meeting password and ‘date and time’. 

 

VSX3000 and V500 version 5.X software does not support provisioning.  If you try to 
provision endpoints with this software, you will see in the ‘Status Details’ the message, 
“An error occurred during the last provision attempt”.

 

7. 

Call Detail Report – 

 

If the Call Detail Record database is large (i.e., >8 MB), performing a Call Detail Record 
with all options selected results in hampered performance due to maximum CPU usage 
and a script timeout error.  

ViewStation version 7.5.1 and below and ViewStation FX version 6.0 and below do not 
report the date/time to CDR reports after CDR synchronization. 

 

The bandwidth is not recorded in the CDR for ViaVideo. 

 

CDR Maintenance will not archive the cause code and the reason.

 

The ViewStation and FX endpoint will send account numbers, which will be recorded in 
CDR, even though it did not originate the call or it did not have Account Validation 
enabled. 

 

With the ViewStation or FX, CDR synchronization does not synchronize properly when 
endpoints are in a call. Invalid data can be written to the CDRlog.mdb (Ex. An IP address 
is written for the account number instead of an actual account number). 

8. 

Device Tracing - 

Telnet tracing will not work if there is already a Telnet session created on  any 

of the devices that support this feature.

 

9. 

Polycom Interoperability - 

The Polycom Data Store portion of the installation fails if 

WebCommander was previously installed because of a port conflict between the Global 
Management MSDE and the existing MSDE installed by the WebCommander. It is recommended 
that WebCommander and Global Management not share the same server.  

10. 

Backup/Restore – 

 

10/6/2004  

Page 12 of 13

 

           

Global Management System 7.0.0

 

Содержание Global Management System 7.0.0

Страница 1: ... Requirements 3 Server Requirements 3 Client Requirements 3 Endpoint Requirements 3 Installation Notes Licensing 5 Key Code Installation Requirement 5 New Installation 5 Upgrading 5 Logging into Global Management System 9 Frequently Asked Questions FAQs 10 Bugs Fixed Since 6 00 Release 11 Bugs Fixed Since 6 01 Release 11 Bugs Fixed Since 6 11 Release 11 Known Issues in 7 0 0 11 Windows 2003 Server...

Страница 2: ...d email notification Remote Alert Log email alerts System Mgmt Video snapshot for V series Global Directory E 164 column Global Directory Type column displays the model of the dynamic endpoint registered 10 6 2004 Page 2 of 13 Global Management System 7 0 0 ...

Страница 3: ...wing OS o Windows XP o Windows 2000 Professional or Server o Windows 98 o Windows NY 4 0 Workstation or Server Microsoft Internet Explorer 5 0 or higher IE 6 0 is recommended In addition the browser must be Java enabled for some graphics to be displayed correctly Also the browser must be set to allow per session cookie in the Security setting of the Internet Options of the browser This setting is ...

Страница 4: ...updates If this port is blocked cached or proxied Global Management System will not receive status updates from the system this will prevent many features of Global Management System from working correctly In order for the endpoints to register to the Global Directory the following port on the firewall must be opened o ViewStation and V Series TCP on port 3601 o iPower TCP on port 3601 o ViaVideo ...

Страница 5: ...ther print the page or write down the License Number Serial Number and Key Code You must have this information to install your software Upgrading Key codes will only be administered to customers who are under a maintenance contract that entitles them to software updates and technical support If you are under maintenance and have not received a key please do the following 1 Register your product se...

Страница 6: ...d then re install MSDE the error message Setup failed to configure the server Refer to the server error logs and setup error logs for more information may appear If this is the case simply delete the Microsoft SQL Server folder under C Program Files and try again o In most cases there is no need to install MSDE again if Global Management is uninstalled and reinstalled The installer will detect the...

Страница 7: ...he Setup application will launch the Global Management System installer If Polycom Datastore is not detected the installer will prompt you to install Polycom Datastore o The Data Store installation will prompt the user to install the JBDC drivers if it detects that the drivers don t exist Follow the screen instructions Figure 2 There is no need to exit the current installation at this time o Once ...

Страница 8: ... via another method or with a different sa password then the user should use the currently defined password Figure 3 Login screen for MSDE o In some cases there may be an error message that states Error 1500 Another installation is in progress You must complete that installation before continuing this one at the end of the Polycom Data Store installation If this occurs wait a moment before clickin...

Страница 9: ...To login into Global Management System from the web interface browse to http servername pwx admin asp or http IP address pwx admin asp If the Global Management System is being installed for the first time the username is admin and password is blank Note After logging in for the first time the user will be forced to change the password from a blank password to a password containing up to 10 charact...

Страница 10: ...Management Systems No reinstallation of MSDE and the JBDC drivers aren t necessary if the version of Global Management Systems to be installed is the same as the previous uninstalled version These drivers should be installed once and should not be uninstalled o If Global Management System is outside the firewall and the endpoints are inside the firewall will Provisioning work If Global Management ...

Страница 11: ...sword policy requires mixed upper lower case or special characters then the user account IGMS_Service cannot be created during the installation As a result both the Polycom Global Address Book and Global Address Book Replicator services will not install and the global address book functionality will not work A work around is to remove the password restriction and reinstall Global Management System...

Страница 12: ...n to select the file Click OK in the Add File window Click Set extension status to Allowed so that the changes are enabled Click OK in the New Web Service Extension window to save your changes 6 Provisioning o In VSX 7000 version 5 1 1 the following fields cannot be provisioned admin password meeting password and date and time o VSX3000 and V500 version 5 X software does not support provisioning I...

Страница 13: ... to the correct Web content zone which connects to Global Management System and select Custom Level and reset to Medium 3 Windows 2003 does not include Java components This must be installed if Global Management System is installed on a Windows 2003 server and you wish to browse the Global Management System pages from the server itself leaving the Java components uninstalled will NOT impact the fu...

Отзывы: