Bugs Fixed Since 6.00 Release
1.
Global Directory –
Set Client Password was not retained during software upgrade and in
Backup/Restore.
2.
Call Detail Report –
Now contains an enable checkbox for CDR Synchronization Configuration
(located in Server Preferences)
Bugs Fixed Since 6.01 Release
1.
Global Directory –
If there are H.320 only or H.323 only listed endpoints in the Global
Directory, the endpoints couldn’t see the other endpoints in their address book.
2.
Provisioning –
The Admin password field has been added back as a provisionable field in
ViewStation and V-Series endpoints.
3.
CDR Maintenance -
VSX 7000 can now be configured for the scheduled maintenance.
Bugs Fixed Since 6.11 Release
1.
Global Directory –
On Viewstations, exporting the address book, would export the ISDN
number but import the gateway number.
2.
Global Directory –
Static entries were displayed with a space instead of a dot between the
international dialing prefix and the country code.
3.
Provisioning –
Provision for FX’s Visual Concert display type and graphics monitor display
type.
4.
Provisioning –
Provision for FX’s QOS fields.
5.
Provisioning –
Provision for video, audio and far end camera control QOS for the V-series.
Known Issues in 7.0.0
1.
Installation –
o
At the end of the MSDE installation if the installation prompts for a reboot the reboot
should be performed after the installation of MSDE; otherwise Polycom Data Store will
not install.
o
If the server password policy requires mixed upper-lower case or special characters, then
the user account “IGMS_Service” cannot be created during the installation. As a result,
both the Polycom Global Address Book and Global Address Book Replicator services will
not install and the global address book functionality will not work. A work around is to
remove the password restriction and reinstall Global Management System.
o
Uninstallation of some previous Global Management System fails with the message
“Fatal error during installation." if Microsoft Installer 2.0 is installed. Contact Polycom
support for directions on a manual uninstall.
2.
System Management
– ViaVideo does not send call status events to Global Management
System when using Windows 2003.
3.
Database –
o
Unlike passwords stored in MS Access database, the passwords stored in MSDE are not
masked.
o
The database may take a couple of minutes to startup if there are more than 2000 entries
in the Global Address Book. If the Global Address Book is accessed from the endpoint
during the Global Management System startup period, global entries do not appear in the
Global Directory.
4.
Global Directory –
o
When iPowers are registered to a gatekeeper and have been provided with an E.164
number by the gatekeeper, the IP address will be displayed in the Global Address Book
instead of its E.164 number.
o
When dynamic endpoints are deleted from the Global Directory and an endpoint re-
registers with the Global Directory, it takes 2 minutes or more to re-register with the
Global Directory. A faster way to register is to reboot the endpoint.
10/6/2004
Page 11 of 13
Global Management System 7.0.0