DETAIL A
DETAIL B
Intermediate Purlin Installation - Part 1
17
AK-210302
17
A
B
Intermediate
Purlin
Wind Brace
FC1002
(End Frame)
Wind Brace
KH1000
PURLIN FASTENER
NB1809
1" Self-Drill Screw
End Frame
RS5000
Round Black Plug
HP3340
Intermediate Frame
HP3340
1
1
2
3
1.
Install first piece of
HP3340
flush to outside of
End Frame approx. 4' 2 7/8" from break at the
top of
FC1002
. Connect
HP3340
to End Frame
using
KH1000
. Install
RS5000
Plug into
HP3340
(see Detail A).
2.
At intermediate frames, use
FT4040
to attach
the
HP3340
. Maintain a consistent distance between
the
HP3340
and the ridge to ensure the purlins run
parallel.
3
. Repeat process for opposite side Intermediate Purlin.