We thank you for purchase of the personal radiation detector of “Polimaster” 

Before  the  beginning  of  operation  with  the  personal  radiation  detector  you  should  get 

acquainted with the present manual.  

!

 

During  the  search  of  radiation  sources  observe  the  existing  rules  of  operation  with  radio 

active  materials and sources, as well as the standards of radiation safety.  

 

GENERAL INFORMATION

1

 

The personal radiation detector 
 
 
 
 
 
 

 
(hereinafter referred to as the indicator) is intended for searching (detection and localization) of radio 

active (and nuclear materials)

2

 by means of the analysis of the counting speed of impulses delivered from the 

detector outlet at registration  of gamma (and neutron)

radiation with indication on a LCD: 

- the average counting speed of gamma radiation; 
- the average counting speed of neutron radiation 

средней

 

скорости

 

счета

 

нейтронного

 

излучения

 

(

in the devices having the detector of neutron radiation

2

); 

- power of the ambient equivalent of a dose of gamma radiations 

H

*

(10) along the line 

137

Cs in the 

collimated radiation (hereinafter referred to  as “MED”). 

 
The indicator is not a meter. 

 
The indicator can be operated both in premises and in the open air. The indicator can be used by a 

wide circle of consumers, who are by their mode of activities related to detection and localization of sources 
of the ionizing emissions.  

 
The  indicator  is  made  as  an  explosion-proof  model.  The  indicator  relates  to  the  explosion-proof 

electric equipment  of group II, sub-group IIC. By the level of explosion protection the indicator relates to 
the especially explosion-proof electrical equipment and is intended for the use in potentially explosion-proof 
environments (zone 0). The type of indicator explosion protection is “the sparkle-proof electric circuit ia”.  

 
The history of indicator operation is retained in the power-independent storage and can be transferred 

to a personal computer (PC) via the infra-red (IR) communication channel. 

 

 
 

                                                           

1

 In the process of indicator manufacture amendments may be entered to the electric circuit, construction, external execution and software, which do not influence 

the technical and metrological specifications and, therefore, not reflected in the present manual.  
 

2

 

РМ

1703GNO, 

РМ

1703GNA, 

РМ

1703GNB

 

• 

РМ

 1703

М

-

О

 

• 

РМ

 1703

МА

 

• 

РМ

 1703

МВ

 

• 

РМ

 1703GN

О

 

• 

РМ

 1703GN

А

  

• 

РМ

 1703GN

В

  

• 

РМ

 1703

М

-

О

• 

РМ

 1703

М

-

О

1A 

Содержание PM 1703GNA

Страница 1: ...POLIMASTER PERSONAL RADIATION DETECTORS 1703 1703GN 1703 1703GN 1703 1703GN 1703 1 1703 1 OPERATION MANUAL http www polimaster com...

Страница 2: ...Indication mode of neutrons 17 Indication mode of the average speed of and count of neutrons over the time of accumulation 17 Quick switching of sound or vibration indication 17 Communication mode by...

Страница 3: ...erred to as MED The indicator is not a meter The indicator can be operated both in premises and in the open air The indicator can be used by a wide circle of consumers who are by their mode of activit...

Страница 4: ...oth type Possibility of identification of the radio nuclide composition of the substance with the aid of ATTENTION The indicators may differ by the totality of included activated operation modes Opera...

Страница 5: ...1 Personal radiation detector 1703GNO 1 Personal radiation detector 1703GNA 1 Personal radiation detector 1703GN 1 Disk software on CD 1 1 1 1 1 1 1 1 Panasonic POWER LINE LR6 power supply cell 1 1 1...

Страница 6: ...neutron radiation registration 1703GN 1703GN 1703GN From heat to 14 0 MeV Range of indication of MED of photon radiation 1703 1 1703 1A 1703 1703GN 1703 1703 1703GN 1703GN 0 01 9999 mc v h 1 1000 mR h...

Страница 7: ...corded events to the indicator storage by 1000 Terms of operation range of ambient temperatures relative humidity From minus 30 C to 50 22 F to 122 F LCD from minus 15 C to plus 50 by 95 at 35 C 95 F...

Страница 8: ...quirements of IEC 60079 0 owing to the following designing and circuit technical solutions provision of the normal degree of mechanical strength of the indicator casing in accordance with the requirem...

Страница 9: ...irected inside the indicator the cover of the supply section is to be restored When the supply cell is installed the indicator is automatically switched on During switching on and during operation of...

Страница 10: ...ion test CAL OL OFF 1 3 etc an indication type sound or vibration 6 the analogue scale consisting of 19 segments is intended for time indication to completion of the internal processor tests reduction...

Страница 11: ...t the LCD for several seconds After completion of the tests the indicator must be shifted to the calibration mode by the background level except for devices having the search mode 0 9 the analogue sca...

Страница 12: ...ing analogue scale Tests are performed The time to completion of the test is displayed in relative units on the analogue scale in the form of the reducing number of the indicated segments After the te...

Страница 13: ...function may be switched on in the mode of communication with the PC Automatic calibration makes it possible to automatically retain the high sensitivity at reduction of the background level and avoid...

Страница 14: ...he threshold value indication light sound and or vibrating is switched on 3 The operation threshold for the neutron channel21 c The minimum detection level calculated in the calibration mode and takin...

Страница 15: ...ization can be continued If necessary these actions cam be repeated several times up to location of II During localization of the source of neutron2 or mixed gamma and neutron radiations the sound and...

Страница 16: ...ation source 2 The safety threshold the 2nd threshold by MED is only set in the mode of communication with a PC by the user administrator The range of threshold setting is equal to 10 7000 R h 0 1 70...

Страница 17: ...E SPEED OF NEUTRON RADIATION INDICATION DURING ACCUMULATION 2 In this mode in the upper line of LCD the average count time is shown during accumulation time s 1 The lower LCD line shows the value of t...

Страница 18: ...the indicator enters after approximately 1 minute the sleeping mode and being so LCD will have the following forms the radio channel is on no communication with the P the radio channel is on communica...

Страница 19: ...LIGHT push button increase the preset value of n factor with pitch 0 1 Subsequent pressings of the MODE push button increase the preset value of n factor with pitch 0 1 If the push buttons are kept pr...

Страница 20: ...of the searching threshold by MED will blink by indicating its possible change If the LIGHT button was not pressed during the said time interval the indicator automatically returns to the working mode...

Страница 21: ...ode MODE OF INDICATION SETTINGS ON OFF OF SOUND AND OR VIBRATING INDICATION The state selection on off of vibrating and sound indicators from the front panel is possible if this mode is allowed at set...

Страница 22: ...ce then at entering the mode of sound volume setting Aud note will be indicated on the LCD as well as the preset sound indicator value from 1 to 5 For changing the sound volume a LIGHT push button sho...

Страница 23: ...omatic start up is supported Operation with the PP is described in th Help site in the attached textual document which are installed along with the user s software For switching on the communication m...

Страница 24: ...tion is performed by wiping with clothes moistened in ethyl spirit replacement of a supply cell in the explosion hazard area is strictly prohibited In case of visible mechanical damages of the casing...

Страница 25: ...anufacturer s permit The warranty does not concern the indicators at expiry of the warranty operation term if the indicator is purchased within the limits of the warranty storage period in case of the...

Страница 26: ...nconformity for which Polimaster is responsible Purchaser shall inform Polimaster of the nature of such defect or nonconformity in reasonable detail and shall request authorization from Polimaster to...

Страница 27: ...to modes 1 2 or 3 5 Mode 0 9 Mode of relative indication 0 9 Can be ON autonomous or combined with modes 2 or 3 6 Auto calibration Impossible in mode 5 7 Search in measurement mode Possible only in co...

Страница 28: ...t threshold count neutrons Only for mode 5 threshold 1 0 99 0 s 1 with interval 0 5 advisable 1 5 s 1 Additional settings 14 Interval of history record min 15 Resolution of coefficient variation n 16...

Отзывы: