COMMUNICATION MODE WITH PC. INDICATOR PARAMETERS 
 
ATTENTION! Operation in the communication mode with  a PC is intended for a trained user 

or the user-administrator. 

Access  to  the  communication  mode  with    a  PC  for  an  ordinary  user  is  protected  with  the 

password. 

 
Communication mode  with a PC by IR communication channel 

 

For  indicator  operation  in  this  mode  a  PC  with  IrDA  should  be  used  or  an  adapter  of  the  IR 

communication channel supplied along with  the indicator by an individual order (see the complete set) and 
the user’s program (

ПП

РМ

17

ХХ

_14

ХХ

, supplied at the CD. 

Minimum requirements for the computer and its software: 
-

Р

100; 

-32 

М

byte ROM; 

-Windows 98, 2000, XP (small print in  Windows set); 
-20 

М

byte of free space on HD plus the free space for the formed data base; 

-monitor resolution 800

х

600; 

-IrDA. 
If  the  built-in  IrDA  is  unavailable  in  the  computer,  the  IR  communication  channel  should  be  used 

which  is  to  be  supplied  as  per  individual  order.  For  connection  of  the  adapter  of  the  IR  communication 
channel the adapter cable is to be linked with a PC communication port.  

 
For PP setting  a CD with the software should be used included to the supply set. 

SETUP.EXE 

program  is  to  be  started  at  the  computer  by  using  the  installation  document  - 

install.doc

. (the automatic start-up is supported). 

Operation  with  the  PP  is  described  in  th

е

  Help  site  in  the  attached  textual  document  which  are 

installed along with the user’s software.  

 

For  switching  on  the  communication  mode  with  a  PC  an  indicator  should  be 

placed  at  the  distance  of  10-12  cm  from  an  adapter  window  of  the  (IrDA) 
communication channel, and  a  LIGHT  push button should be pressed. As soon as the 
indicator enters the mode of information exchange, “Ir” message will be illuminated  on 

the LCD.  

*Note

 – 

The indicator is automatically switched off  ( "OFF" note is indicated on the LCD)after 

reading the indicator operation history in the mode of communication with a PC. 

 
INDICATOR PARAMETERS 

Indicator parameters are set up in the communication mode with a PC user-administrator (the access is 

protected with a password).  

The manufacturer sets up the access password  – 1. 
The indicator is supplied to the user along with initial settings which comply with the chart of orders 

(see attachment A).  

During  operation  in  the  communication  mode  with  a  PC  the  user-administrator  may  fulfill  the 

following actions: 

In the information system 

- to register belonging of the indicator to a specific user; 
- to remember the time of indicator sending and returning; 

*

to read information from the indicator storage, including the history of its operation: 

-the indicator number; 
-time of indicator on/off; 
-current MED value by the gamma channel via the consecutive time interval set up by 

the user; 

Содержание PM 1703GNA

Страница 1: ...POLIMASTER PERSONAL RADIATION DETECTORS 1703 1703GN 1703 1703GN 1703 1703GN 1703 1 1703 1 OPERATION MANUAL http www polimaster com...

Страница 2: ...Indication mode of neutrons 17 Indication mode of the average speed of and count of neutrons over the time of accumulation 17 Quick switching of sound or vibration indication 17 Communication mode by...

Страница 3: ...erred to as MED The indicator is not a meter The indicator can be operated both in premises and in the open air The indicator can be used by a wide circle of consumers who are by their mode of activit...

Страница 4: ...oth type Possibility of identification of the radio nuclide composition of the substance with the aid of ATTENTION The indicators may differ by the totality of included activated operation modes Opera...

Страница 5: ...1 Personal radiation detector 1703GNO 1 Personal radiation detector 1703GNA 1 Personal radiation detector 1703GN 1 Disk software on CD 1 1 1 1 1 1 1 1 Panasonic POWER LINE LR6 power supply cell 1 1 1...

Страница 6: ...neutron radiation registration 1703GN 1703GN 1703GN From heat to 14 0 MeV Range of indication of MED of photon radiation 1703 1 1703 1A 1703 1703GN 1703 1703 1703GN 1703GN 0 01 9999 mc v h 1 1000 mR h...

Страница 7: ...corded events to the indicator storage by 1000 Terms of operation range of ambient temperatures relative humidity From minus 30 C to 50 22 F to 122 F LCD from minus 15 C to plus 50 by 95 at 35 C 95 F...

Страница 8: ...quirements of IEC 60079 0 owing to the following designing and circuit technical solutions provision of the normal degree of mechanical strength of the indicator casing in accordance with the requirem...

Страница 9: ...irected inside the indicator the cover of the supply section is to be restored When the supply cell is installed the indicator is automatically switched on During switching on and during operation of...

Страница 10: ...ion test CAL OL OFF 1 3 etc an indication type sound or vibration 6 the analogue scale consisting of 19 segments is intended for time indication to completion of the internal processor tests reduction...

Страница 11: ...t the LCD for several seconds After completion of the tests the indicator must be shifted to the calibration mode by the background level except for devices having the search mode 0 9 the analogue sca...

Страница 12: ...ing analogue scale Tests are performed The time to completion of the test is displayed in relative units on the analogue scale in the form of the reducing number of the indicated segments After the te...

Страница 13: ...function may be switched on in the mode of communication with the PC Automatic calibration makes it possible to automatically retain the high sensitivity at reduction of the background level and avoid...

Страница 14: ...he threshold value indication light sound and or vibrating is switched on 3 The operation threshold for the neutron channel21 c The minimum detection level calculated in the calibration mode and takin...

Страница 15: ...ization can be continued If necessary these actions cam be repeated several times up to location of II During localization of the source of neutron2 or mixed gamma and neutron radiations the sound and...

Страница 16: ...ation source 2 The safety threshold the 2nd threshold by MED is only set in the mode of communication with a PC by the user administrator The range of threshold setting is equal to 10 7000 R h 0 1 70...

Страница 17: ...E SPEED OF NEUTRON RADIATION INDICATION DURING ACCUMULATION 2 In this mode in the upper line of LCD the average count time is shown during accumulation time s 1 The lower LCD line shows the value of t...

Страница 18: ...the indicator enters after approximately 1 minute the sleeping mode and being so LCD will have the following forms the radio channel is on no communication with the P the radio channel is on communica...

Страница 19: ...LIGHT push button increase the preset value of n factor with pitch 0 1 Subsequent pressings of the MODE push button increase the preset value of n factor with pitch 0 1 If the push buttons are kept pr...

Страница 20: ...of the searching threshold by MED will blink by indicating its possible change If the LIGHT button was not pressed during the said time interval the indicator automatically returns to the working mode...

Страница 21: ...ode MODE OF INDICATION SETTINGS ON OFF OF SOUND AND OR VIBRATING INDICATION The state selection on off of vibrating and sound indicators from the front panel is possible if this mode is allowed at set...

Страница 22: ...ce then at entering the mode of sound volume setting Aud note will be indicated on the LCD as well as the preset sound indicator value from 1 to 5 For changing the sound volume a LIGHT push button sho...

Страница 23: ...omatic start up is supported Operation with the PP is described in th Help site in the attached textual document which are installed along with the user s software For switching on the communication m...

Страница 24: ...tion is performed by wiping with clothes moistened in ethyl spirit replacement of a supply cell in the explosion hazard area is strictly prohibited In case of visible mechanical damages of the casing...

Страница 25: ...anufacturer s permit The warranty does not concern the indicators at expiry of the warranty operation term if the indicator is purchased within the limits of the warranty storage period in case of the...

Страница 26: ...nconformity for which Polimaster is responsible Purchaser shall inform Polimaster of the nature of such defect or nonconformity in reasonable detail and shall request authorization from Polimaster to...

Страница 27: ...to modes 1 2 or 3 5 Mode 0 9 Mode of relative indication 0 9 Can be ON autonomous or combined with modes 2 or 3 6 Auto calibration Impossible in mode 5 7 Search in measurement mode Possible only in co...

Страница 28: ...t threshold count neutrons Only for mode 5 threshold 1 0 99 0 s 1 with interval 0 5 advisable 1 5 s 1 Additional settings 14 Interval of history record min 15 Resolution of coefficient variation n 16...

Отзывы: