Polimaster PM 1703GNA Скачать руководство пользователя страница 14

 

14 

 
In this mode the indicator operation is carried out to the following thresholds: 
 

1)

  The  fixed 

threshold  by  MED

,  set  up  in  the  communication  mode  with  the  PC  by  the  user-

administrator; 
 

When the installed threshold is exceeded by MED the indicator sends light, sound and/or vibrating 

signals. Being so single-tone periodical signals are sent with the constant interval and duration 1 s by making 
it possible for the user to acknowledge indication when threshold by MED is exceeded  from the operation 
threshold.  

2)

 

The  gamma  channel  operation  threshold 

(the  minimum  detection  level)  calculated  in  the 

calibration  mode  and  taking  into  account  the  changes  in  the  background  level.  When  the  gamma  channel 
threshold is exceeded the indicator light, sound and/or vibrating signals. Being so, frequency of the received 
signals is constant and is increased along with the exceeded 

gamma channel operation threshold

The whole range of energies of the indicator gamma radiations is divided into four energy channels. 

Three channels correspond to  areas of interest for low, middle and high energies, and the 4

th

 one – to the 

whole range of energies of the gamma radiation. 

The operation threshold 

is calculated for every channel. 

The processor counts impulses every 0,25 s by each channel from the detection block, and it keeps 

the amount  of  impulses during  the  counting.  Being  so,   every  0,25  s  the number of  impulses  over  the last 
(new)  interval  is  added  to  the  current  amount,  and  the  number  of  impulses  during  the  first  (the  oldest) 
interval is deducted from the sum of impulses (the current average). So, the number of impulses stored in the 
processor for each channel is renewed every 0,25 s. 

The  current  average  number  of  impulses  is  compared  every  0,25  s  with 

operation  thresholds 

for 

each channel,

 which are calculated in the calibration mode (clause 2.2.3)

. If the current average value of 

the  number  of  impulses  by  any  channel  exceeds  the  threshold  value,  indication  (light,  sound  and/or 
vibrating) is switched on.  

 

3)

 

The operation threshold for the neutron channel

2

1

 

(The minimum  detection level), calculated 

in  the  calibration    mode  and  taking  into  account  the  changes  in  the  background  level.  If  the  operation 
threshold is exceeded the indicator sends light, sound and/or vibrating signals. Being so, double signals are 
sent with the permanent interval and duration, what making it possible for the user to find indication when 
the operation threshold of gamma channel exceeds  operation of the neutron channel. 

 

 

In  the  searching  mode  the  device resolves  the  problems  of  detection  and  localization  of  sources of 

gamma and neutron radiation. 

 

 

 

Detection of sources of gamma and neutron 

2

 radiation (II) 

For II detection the device should be located so that the rear side  (wherein the clamp is fixed) should 

be directed  to the tested object . The closer the device is placed to the tested object (luggage, a human being, 
a container, a vehicle, etc) and the slower it travels along the object, detection efficiency is higher.  

 

 

For II detection under conditions when sound signals of the indicator may be not heard (for example, 

excessive noise) the vibrating and light indicator should be used. 
 

One should remember that indicator sensitivity and frequency of false operations depend on: 

 

- the preset value of n factor by the gamma channel

 

- the preset value of n factor by the neutron channel

 

- the background level calculated by the indicator in the calibration mode by the background level. 

In  case  when  automatic  calibration  is  switched  on  in  the  communication  mode  with  a  PC,  the 

indicator will automatically take into account slow changes of the background level and calibrate by a new 
background level approximately after every ten minutes with the reduction of  the background level or after 
somewhat bigger intervals during increase of the background level. However, automatic calibration will be 
carried  out  under  conditions  of  absence  of  indicator  operations  or  sharp  changes  of  the  background  level 
over certain intervals defined by the algorithm. 

                                                           

2

 

РМ

1703GNO, 

РМ

1703GNA, 

РМ

1703GNB

 

Содержание PM 1703GNA

Страница 1: ...POLIMASTER PERSONAL RADIATION DETECTORS 1703 1703GN 1703 1703GN 1703 1703GN 1703 1 1703 1 OPERATION MANUAL http www polimaster com...

Страница 2: ...Indication mode of neutrons 17 Indication mode of the average speed of and count of neutrons over the time of accumulation 17 Quick switching of sound or vibration indication 17 Communication mode by...

Страница 3: ...erred to as MED The indicator is not a meter The indicator can be operated both in premises and in the open air The indicator can be used by a wide circle of consumers who are by their mode of activit...

Страница 4: ...oth type Possibility of identification of the radio nuclide composition of the substance with the aid of ATTENTION The indicators may differ by the totality of included activated operation modes Opera...

Страница 5: ...1 Personal radiation detector 1703GNO 1 Personal radiation detector 1703GNA 1 Personal radiation detector 1703GN 1 Disk software on CD 1 1 1 1 1 1 1 1 Panasonic POWER LINE LR6 power supply cell 1 1 1...

Страница 6: ...neutron radiation registration 1703GN 1703GN 1703GN From heat to 14 0 MeV Range of indication of MED of photon radiation 1703 1 1703 1A 1703 1703GN 1703 1703 1703GN 1703GN 0 01 9999 mc v h 1 1000 mR h...

Страница 7: ...corded events to the indicator storage by 1000 Terms of operation range of ambient temperatures relative humidity From minus 30 C to 50 22 F to 122 F LCD from minus 15 C to plus 50 by 95 at 35 C 95 F...

Страница 8: ...quirements of IEC 60079 0 owing to the following designing and circuit technical solutions provision of the normal degree of mechanical strength of the indicator casing in accordance with the requirem...

Страница 9: ...irected inside the indicator the cover of the supply section is to be restored When the supply cell is installed the indicator is automatically switched on During switching on and during operation of...

Страница 10: ...ion test CAL OL OFF 1 3 etc an indication type sound or vibration 6 the analogue scale consisting of 19 segments is intended for time indication to completion of the internal processor tests reduction...

Страница 11: ...t the LCD for several seconds After completion of the tests the indicator must be shifted to the calibration mode by the background level except for devices having the search mode 0 9 the analogue sca...

Страница 12: ...ing analogue scale Tests are performed The time to completion of the test is displayed in relative units on the analogue scale in the form of the reducing number of the indicated segments After the te...

Страница 13: ...function may be switched on in the mode of communication with the PC Automatic calibration makes it possible to automatically retain the high sensitivity at reduction of the background level and avoid...

Страница 14: ...he threshold value indication light sound and or vibrating is switched on 3 The operation threshold for the neutron channel21 c The minimum detection level calculated in the calibration mode and takin...

Страница 15: ...ization can be continued If necessary these actions cam be repeated several times up to location of II During localization of the source of neutron2 or mixed gamma and neutron radiations the sound and...

Страница 16: ...ation source 2 The safety threshold the 2nd threshold by MED is only set in the mode of communication with a PC by the user administrator The range of threshold setting is equal to 10 7000 R h 0 1 70...

Страница 17: ...E SPEED OF NEUTRON RADIATION INDICATION DURING ACCUMULATION 2 In this mode in the upper line of LCD the average count time is shown during accumulation time s 1 The lower LCD line shows the value of t...

Страница 18: ...the indicator enters after approximately 1 minute the sleeping mode and being so LCD will have the following forms the radio channel is on no communication with the P the radio channel is on communica...

Страница 19: ...LIGHT push button increase the preset value of n factor with pitch 0 1 Subsequent pressings of the MODE push button increase the preset value of n factor with pitch 0 1 If the push buttons are kept pr...

Страница 20: ...of the searching threshold by MED will blink by indicating its possible change If the LIGHT button was not pressed during the said time interval the indicator automatically returns to the working mode...

Страница 21: ...ode MODE OF INDICATION SETTINGS ON OFF OF SOUND AND OR VIBRATING INDICATION The state selection on off of vibrating and sound indicators from the front panel is possible if this mode is allowed at set...

Страница 22: ...ce then at entering the mode of sound volume setting Aud note will be indicated on the LCD as well as the preset sound indicator value from 1 to 5 For changing the sound volume a LIGHT push button sho...

Страница 23: ...omatic start up is supported Operation with the PP is described in th Help site in the attached textual document which are installed along with the user s software For switching on the communication m...

Страница 24: ...tion is performed by wiping with clothes moistened in ethyl spirit replacement of a supply cell in the explosion hazard area is strictly prohibited In case of visible mechanical damages of the casing...

Страница 25: ...anufacturer s permit The warranty does not concern the indicators at expiry of the warranty operation term if the indicator is purchased within the limits of the warranty storage period in case of the...

Страница 26: ...nconformity for which Polimaster is responsible Purchaser shall inform Polimaster of the nature of such defect or nonconformity in reasonable detail and shall request authorization from Polimaster to...

Страница 27: ...to modes 1 2 or 3 5 Mode 0 9 Mode of relative indication 0 9 Can be ON autonomous or combined with modes 2 or 3 6 Auto calibration Impossible in mode 5 7 Search in measurement mode Possible only in co...

Страница 28: ...t threshold count neutrons Only for mode 5 threshold 1 0 99 0 s 1 with interval 0 5 advisable 1 5 s 1 Additional settings 14 Interval of history record min 15 Resolution of coefficient variation n 16...

Отзывы: