Telephone Helpline: 1300225960
If the temperature
measured by
the pin probe
reaches the
chilling endpoint
temperature prior
to expiry of the
maximum chilling
time duration:
• the device will switch to storage mode
• the display will show the message “End”
• the buzzer will sound for the period of time set by parameter AA
• press any key to mute the buzzer; press once more to cancel the message
“End”
If the temperature
measured by the
pin probe does
not reach the
chilling endpoint
temperature prior
to expiry of the
maximum chilling
time duration:
• chilling will continue
• the LED
will flash and the LED
will be on
• the buzzer will sound
• press
several times to:
- mute the buzzer
- display the time elapsed since the maximum chilling time expired
- display the cabinet temperature
- display the message “PoS”
- exit the procedure, or leave for 15 seconds
When the
temperature
measured by
the pin probe
reaches the
chilling endpoint
temperature:
• the device switches to storage mode
• the LED
will continue to flash and the LED
will stay on
• the display will show the message “End”
• the buzzer will sound for the period of time set by parameter AA
• press any key to mute the buzzer; press once more to cancel the message
“End”
During storage:
• the display shows the cabinet temperature
• if chilling had a positive outcome, the LEDs
and
will be on; if
chilling had a negative outcome, the LEDs
and
will be on and the
LED
will flash.
• the parameter r9 sets the operational set point
• press
several times to:
- display the message “PoS”
- exit the procedure, or leave for 15 seconds
To interrupt the
cycle:
• press
for 2 seconds
Set-Temperature Negative Chilling And Storage Cycle
Prior to starting
the cycle:
• A test is run in order to check correct pin probe insertion
- if the outcome of the test is positive, the cycle will be started
- if the outcome of the test is negative, the cycle will be started in timed
mode