5
AU
AU
Telephone Helpline: 1300225960
Insert the food probe
• Before selecting which cycle to use, the probe must be inserted into the food. This allows the internal
temperature of the food to be measured.
• It is important that the probe is correctly connected to the unit.
Note: To prevent bacterial contamination or contamination of any other
biological nature, the needle probe must be disinfected after use.
Control Panel
Alarm LED
Minute LED
Degree
Celsius LED
Degree
Fahrenheit LED
Timed
Chilling LED
Set-Temperature
Chilling LED
Storage LED
In the “on” state, during normal operation, the display shows:
• the amount of time remaining for a timed blast chilling operation, if this is ongoing
• the temperature measured by the pin probe if a set-temperature chilling operation is ongoing
• the temperature of the cabinet, if storage is ongoing.
In “stand-by” mode, during normal operation, the display shows the temperature of the cabinet for ½
second every 3 seconds.
Signals
LED
Message
Timed Chilling LED
• If on and the LED
is off, a timed chilling operation is ongoing
• If on and the LED
is also on, a post timed-chilling storage operation is ongoing
• If flashing, a timed chilling and storage cycle will have been selected
Set-temperature chilling LED
• If on and the LED
is off, a set-temperature chilling storage operation is ongoing
• If on and the LED
is also on, a post set-temperature chilling storage operation will
be ongoing
• If flashing, a set temperature chilling and storage cycle will have been selected
CK640-A_A5_v1_20190507.indb 5
2019/5/7 15:55