7
AU
AU
Telephone Helpline: 1300225960
Timed Positive Blast Chilling And Storage Cycle
To start the cycle:
• ensure the device is in “stand-by” mode and no procedures are running
• press
to select “PoS” and ensure the LED
is flashing
• press
within 15 seconds: the display will show the duration of the blast
chilling step (in minutes)
• press
or
within 15 seconds to change the value (the setting
remains active until another cycle is selected, when the value assigned by
parameter r1 is restored)
• press
: after 2 minutes, the appliance will run timed positive blast
chilling and storage cycle
During chilling:
• the display shows the residual chilling time remaining
• the LED
is on
• parameter r1 sets the chilling time duration
• parameter r7 sets the operational set point
• press
several times to:
- display the message “PoS”
- display the cabinet temperature
- exit the procedure, or leave for 15 seconds
Once the chilling
period has
elapsed:
• the device switches to storage mode
• the display shows the message “End”
• the buzzer sounds for the period of time set by parameter AA
• press any key to mute the buzzer; press once more to cancel the message
“End”
During storage:
• the display shows the cabinet temperature
• the LEDs
and
are on
• the parameter r9 sets the operational set point
• press
several times to:
- display the message “PoS”
- exit the procedure, or leave for 15 seconds.
To interrupt the
cycle:
• press
for 2 seconds
Timed Negative Chilling And Storage Cycle
To start the cycle:
• ensure the device is in “stand-by” mode and no procedures are running
• press
to select “nEg” and ensure the LED
is flashing
• press
within 15 seconds: the display will show the duration of the blast
chilling step (in minutes)
• press
or
within 15 seconds to change the value (the setting
remains active until another cycle is selected, when the value assigned by
parameter r2 is restored)
• press
: after 2 minutes, the appliance will run timed negative chilling
and storage cycle
CK640-A_A5_v1_20190507.indb 7
2019/5/7 15:55