SAFETY INSTRUCTIONS

General 

The manufacturer does not accept any liability for damage to

the product or personal injury caused by ignoring of the safety

instructions in this manual, or by negligence during installation, 

use, maintenance, and repair of the product mentioned on the 

cover of this document and any corresponding accessories.

Specific working conditions or used accessories may require

additional safety instructions. Immediately contact your supplier 

if you detect a potential danger when using the product.

The user of the product is always fully responsible for

observing the local safety instructions and regulations.

Observe all applicable safety instructions and regulations.

User manual 

- Everyone working on or with the product, must be familiar

with the contents of this manual and must strictly observe

the instructions therein. The management should instruct the

personnel in accordance with the manual and observe all

instructions and directions given.

- Do not change the order of the steps to perform.

- Keep the manual with the product.

Users 

- The use of this product is exclusively reserved to authorized,

trained and qualified users. Temporary personnel and

personnel in training can only use the product under

supervision and responsibility of skilled engineers.

- Stay alert and keep your attention to your work. Do not use

the product when you are under the influence of drugs,

alcohol or medicine.

- The product is not to be used by children or persons with

reduced physical, sensory or mental capabilities, or lack of

experience and knowledge, unless they have been given 

supervision or instruction.

- Children must be supervised not to play with the product.

Technical specifications

Do not change the specifications given in this manual.

Modifications

Modification of (parts of) the product is not allowed.

Installation

- The installation of this product is exclusively reserved to

authorized, trained and qualified engineers.

- The electric connection must be executed in accordance with

the local codes and requirements. Ensure compliance with

the EMC regulatory arrangements.

- During installation, always use Personal Protective

Equipment (PPE) to avoid injury. This also applies to persons

who enter the work area during installation.

- Use sufficient climbing gear and safety guards when working

on a higher level than 2 meters (local restrictions may

apply).

- Do not install the product in front of entrances and exits

which must be used for emergency services.

- Mind any gas and water pipes and electric cables.

- Make sure that the workspace is well illuminated.

- Stay alert and keep your attention to your work. Do not

install the product when you are under the influence of

drugs, alcohol or medicine.

- Air containing particles such as chromium, nickel, beryllium,

cadmium, lead etc., should never be recycled. This air must

always be brought outside the working area.

Use 

 

- Inspect the product and check it for damage. Verify the 

functioning of the safety features. 

 

- Check the working environment. Do not allow unauthorized 

persons to enter the working environment. 

 

- Protect the product against water and humidity.

 

-

Make sure the room is always sufficiently ventilated; this 

applies especially to confined spaces.

 

- Make sure that the workshop, in the vicinity of the product, 

contains sufficient approved fire extinguishers (suitable for fire 

classes ABC). 

Service, maintenance and repairs

 

- Obey the maintenance intervals given in this manual. Overdue 

maintenance can lead to high costs for repair and revisions and 

can render the guarantee null and void. 

 

- Always use Personal Protective Equipment (PPE) to avoid 

injury. This also applies for persons who enter the work area.

 

-

Make sure the room is sufficiently ventilated. 

 

- Use tools, materials, lubricants and service techniques which 

have been approved by the manufacturer. Never use worn 

tools and do not leave any tools in or on the product. 

 

-

Use sufficient climbing gear and safety guards when working 

on a higher level than 2 metres (local restrictions may apply).

 

- Clean the area afterwards.

INSTALLATION 

4.1 

Preparation

• Determine the installation height of the rail (measured from 

the bottom of the rail).

•  Determine the recommended distance from the end stop to the 

door in the installation table below. 

•  Determine the recommended balancer locking cable (BLC) 

length in the installation table  below.

• 

 After installation, fine tune the BLC if the disconnection point is 

not close enough to the door.

Rail height

Distance end stop/door

Содержание STRA

Страница 1: ...www plymovent com Installation and user manual STRA...

Страница 2: ...f this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer cannot be held responsible for any damage resulting from...

Страница 3: ...MG manual 2 ENGLISH Page Preface 3 1 Introduction 3 2 Product description 3 3 Safety instructions 5 4 Installation 5 5 Use 11 6 Maintenance 12 7 Troubleshooting 13 8 Disposal 13 9 Spare parts 13 TABL...

Страница 4: ...ted the contents of this manual applies to the STRA 1 INTRODUCTION 1 1 Identification of the product The identification plate contains among other things the following data product name serial number...

Страница 5: ...Balancer Locking Cable BLC is to control the point of disconnection As the hose reaches it s maximum length the BLC will bottom out in turn pulling the Magnetic Grip nozzle from the moving vehicle Cra...

Страница 6: ...ys use Personal Protective Equipment PPE to avoid injury This also applies to persons who enter the work area during installation Use sufficient climbing gear and safety guards when working on a highe...

Страница 7: ...or and the exhaust pipe 3 This is the minimum length of the STRA rail Check before installation that this is the minimum required length of the STRA back in application The distance from the end of th...

Страница 8: ...t Drywall ceiling with wood framing locate center of trusses cut strut to span 3 trusses drill 1 4 in pilot holes and mount strut using 3 8 in X 3 1 2 in grade 5 lag bolts Poured or Pre Cast Concrete...

Страница 9: ...duct and lift the rail On the top of the rail lay out 3 8 in holes for the leg mounting feet locations to match the distances between the leg assemblies previously hung from the ceiling The maximum e...

Страница 10: ...icle in the 3 o clock position if looking down at the crab trolley with the balancer at the 12 o clock position Install the balancer 3 using the caribiner hook and safety cable 4 and attach the Balanc...

Страница 11: ...parately delivered manual for installation 4 11 Install the tailpipe connector 1 Distance exhaust pipe truck body 2 Tailpipe 3 Conical tailpipe adapter 4 Tailpipe bracket The distance between the midd...

Страница 12: ...e reducer packs The tailpipe reducer pack enables vehicles with different tailpipe sizes to connect to the Plymovent Magnetic Grabber tailpipe connector This product can be used in combination with th...

Страница 13: ...simple regular maintenance activities are required which are described in this chapter The maintenance activities in the table below can be carried out by the user Component Action Frequency every X...

Страница 14: ...The end stop is located too far from the door Reposition the rail closer to the entry door The swingback of the hose drop after disconnection is too extreme The balancer pre tension is too strong Decr...

Страница 15: ...100 mm 4 0000114046 Steel saddle 5 in 125 mm 5 SDCH For article numbers and prices please refer to the spare part price list 6 Magnetic Grabber For article numbers and prices please refer to the pric...

Страница 16: ...160420 0 STRA MG manual...

Отзывы: