background image

160420/0 STRA MG manual 

EN - 4

STRA extraction rail

The STRA track is delivered in 2 lengths:

STRA-Track - 19.6 ft (5,8 m)

STRA-Track 1/2 - 9.5 ft (2,9 m)

  Side brace

 

 

There are three different lengths available, 20  

 

 

in. (500 mm), 30 in. (750 mm) and 6 ft (1800  

 

 

mm). The brace can be mounted separately or  

 

 

in pairs using the same brackets.

  Side brace clamp kit

 

 

The kit includes two aluminum brackets for   

 

 

one or two side braces, and one clamp. This kit  

 

 

is available in all three side brace lengths.    

 

 

Braces can also be ordered separately. 

    

  Adjustable mounting kit (vertical)

 

 

The kit includes two similar brackets. 

 

 

They can also be used if the roof is angled 

 

 

and they can be mounted in both directions. 

 

 

Maximum angle is 30 degrees. It also includes  

 

 

two STRA brackets for mounting the STRA rail  

                          to the support leg.

  Balancer

 

 

The non-locking spring recoil balancer has a  

 

 

lifting capacity of 17.6 - 37 lbs (8 - 17 kg) with  

 

 

a cable length of 6.6 ft (2.2 m). The main    

 

 

function of the Balancer Locking Cable (BLC) is  

 

 

to control the point of disconnection. As the   

 

 

hose reaches it’s maximum length, the BLC will  

 

 

bottom out, in turn pulling the Magnetic Grip  

 

 

nozzle from the moving vehicle.

Crab trolley

The ventilated sliding crab runs inside of the rail and can be 

positioned anywhere along the rail.

Duct connection 8 in. (Ø 200 mm)

 

 

STRA end caps

  The STRA closed end cap is provided with the  

 

 

rail, and is mounted to the back end of the rail  

 

 

for a back in system, or the entrance end of  

 

 

the rail for a drive through system.

Hose Kit

Hose kits available: 

-  ST (standard temperature) hose, 400

°

F (205

°

C) continuous, 

500

°

F (260

°

C) intermittent, 

-  HT (high temperature) hose, 900

°

F (480

°

C) continuous, 

1,050

°

F (570

°

C) degrees intermittent (upper, mid and lower 

hose)

- Hose diameter is either 4 in. or 5 in. (100 mm or 125 mm)

-  Magnetic Grabber is either 3, 4 or 5 in. (75, 100, or 125 mm)

The different hose packages which contain the following parts:

- Transition parts 

- Exhaust removal hose with clamps

- Hoses: upper, mid and lower hose

- Metal hose saddle

- Safety disconnect handle

- Magnetic Grabber

®

 nozzle

- Magnetic Grabber

®

 conical tailpipe adapter (available in 3, 4, 5, 

6 and 7 in.)

Содержание STRA

Страница 1: ...www plymovent com Installation and user manual STRA...

Страница 2: ...f this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer cannot be held responsible for any damage resulting from...

Страница 3: ...MG manual 2 ENGLISH Page Preface 3 1 Introduction 3 2 Product description 3 3 Safety instructions 5 4 Installation 5 5 Use 11 6 Maintenance 12 7 Troubleshooting 13 8 Disposal 13 9 Spare parts 13 TABL...

Страница 4: ...ted the contents of this manual applies to the STRA 1 INTRODUCTION 1 1 Identification of the product The identification plate contains among other things the following data product name serial number...

Страница 5: ...Balancer Locking Cable BLC is to control the point of disconnection As the hose reaches it s maximum length the BLC will bottom out in turn pulling the Magnetic Grip nozzle from the moving vehicle Cra...

Страница 6: ...ys use Personal Protective Equipment PPE to avoid injury This also applies to persons who enter the work area during installation Use sufficient climbing gear and safety guards when working on a highe...

Страница 7: ...or and the exhaust pipe 3 This is the minimum length of the STRA rail Check before installation that this is the minimum required length of the STRA back in application The distance from the end of th...

Страница 8: ...t Drywall ceiling with wood framing locate center of trusses cut strut to span 3 trusses drill 1 4 in pilot holes and mount strut using 3 8 in X 3 1 2 in grade 5 lag bolts Poured or Pre Cast Concrete...

Страница 9: ...duct and lift the rail On the top of the rail lay out 3 8 in holes for the leg mounting feet locations to match the distances between the leg assemblies previously hung from the ceiling The maximum e...

Страница 10: ...icle in the 3 o clock position if looking down at the crab trolley with the balancer at the 12 o clock position Install the balancer 3 using the caribiner hook and safety cable 4 and attach the Balanc...

Страница 11: ...parately delivered manual for installation 4 11 Install the tailpipe connector 1 Distance exhaust pipe truck body 2 Tailpipe 3 Conical tailpipe adapter 4 Tailpipe bracket The distance between the midd...

Страница 12: ...e reducer packs The tailpipe reducer pack enables vehicles with different tailpipe sizes to connect to the Plymovent Magnetic Grabber tailpipe connector This product can be used in combination with th...

Страница 13: ...simple regular maintenance activities are required which are described in this chapter The maintenance activities in the table below can be carried out by the user Component Action Frequency every X...

Страница 14: ...The end stop is located too far from the door Reposition the rail closer to the entry door The swingback of the hose drop after disconnection is too extreme The balancer pre tension is too strong Decr...

Страница 15: ...100 mm 4 0000114046 Steel saddle 5 in 125 mm 5 SDCH For article numbers and prices please refer to the spare part price list 6 Magnetic Grabber For article numbers and prices please refer to the pric...

Страница 16: ...160420 0 STRA MG manual...

Отзывы: