160420/0 STRA MG manual
EN - 9
• To connect the rail to the fan and the duct system by the
connection socket (3), cut a 19.6 in (500 mm) x 2.3 in. (60
mm) hole in the side of the rail profile. Apply silicone
sealeant to the bottom flange of the duct connector and
attach with the provided self-drilling screws. Repeat this step
if you are using multiple duct connections on longer rails.
4.8
Assemble and hang the hose/grabber
1. Upper hose
2. Saddle
3. Balancer
4. Safety Cable
5. Locking Cable
6. Mid Hose
7. Safety Disconnect Handle
Follow these steps to assemble and align the exhaust hose
assembly:
• Mount the upper hose (1) to the trolley using a hose clamp.
• Attach the upper hose to the short side (from the tab) of the
metal saddle (2). You may need to twist the hose to to have
the u-bend or loop positioned away from the vehicle in the 3
o’clock position if looking down at the crab trolley, with the
balancer at the 12 o’clock position.
•
• Install the balancer (3) using the caribiner hook and safety
cable (4), and attach the Balancer Locking Cable (BLC) to the
carabiner which is attached to the trolley (5). Assemble the
BLC using the length listed in the Installation Table on page
10. Ideally, 6 in. (15 cm) of the Balancer cable should be
exposed when the Grabber nozzle is connected to the
vehicle.
• Install the BLC so that it is on the back side of the balancer
and away from the adjustment locking clip. This will keep the
BLC from coming into contact and potentially breaking the
locking clip. The balancer snap hook should be oriented with
the catch or door of the hook on the same side of the
balancer as the locking clip. This will ensure that the BLC
does not open the snap hook, allowing the BLC to come
loose. The BLC attachment to the metal saddle snap hook
should be opposite of the catch or door so that it does not
open it.