20
2.
As a safe position for the customer to get on or off the lift on intervening
floors. In addition to using the red park button on the remote control, by
selecting the correct option from the menu system, the lift will also stop at
the parking point from the joystick control, enabling the customer to either
get off the lift, or, by pressing the control again continue to the next
charging point.
If an intermediate
charge point is
required, this should
be clamped to the
racking in the correct
position. The 2 core
cable that you
installed earlier will
need terminating.
Strip back the insulator from both cables, connect both brown cores
together using one of the crimp on spade connectors supplied.
At the other end of the rail, take the
2 core cable that you installed in
through the bottom rail of the track
earlier. Strip back the outer insulator
and attach the inner blue core to the
rack using the red crimp on eyelet
connector supplied and fix this to the
racking using the supplied M5 x 10
buttonhead cap screws.
Connect this to the lug on the back
of the charge ramp.
Connect both blue cores together using one of the crimp on eyelet
connectors supplied and attach to the racking using one of the M5 x 10
buttonhead cap screws supplied.
The charge point can be adusted to enable the charge pin on the carriage
to make a good contact but not activate the final limit switch when passing.
Clip all wires neatly to the end stop assembly using the supplied tie wraps
to ensure that they do not foul the carriage as it is moving.
Plug in and turn on the Power supply and test that each charge ramp is
sup33 V.
Содержание Curve Stairlift
Страница 33: ...33 Connection Diagram...
Страница 34: ...34...
Страница 42: ...42 Notes...