33
www.planta.ru.com
Adjustment of running belt
During prolonged use of the treadmill, a situa on may arise when the tension of the web has
weakened - that is, during work it begins to "slip," remaining in place, while the trainee con nues
to make steps. This is not a fault and is solved as follows:
Turn the le adjustment screw clockwise by 1/4 at a me using the
Г
- instrument included in the
set, then repeat the same with the right adjustment screw
(
Pic. C). Be careful: turn both screws at
the same number of revolu ons! If necessary, repeat the procedure un l the web stops slipping.
The adjus ng screws are located on the back of the treadmill.
In case of excessive tension, the walking belt needs to be loosened. To do this, turn both
adjustment screws counterclockwise by the same number of revolu ons (Pic.D). A er adjustment,
leave the treadmill in mo on for another me (1-2 minutes) to check the adjustment result. If
necessary, adjust the web tension again using the same algorithm.
Error code value and solu on
Pic.
A
. Adjus ng the tape offset to the right Pic. B. Adjus ng the tape offset to the le
Code
Error
Solu on
Er1
Instrument board does not receive
signal
1.1. Check if the mains power cable is
damaged;
Er
3
Excessive voltage
2.1
.
Check the voltage value on the supply
line: AC 200-240V;
Pic
.
C
. Tensioning of running belt
Pic
.
D
. Relaxing the tension of running belt