User’s Manual of IGS-20040MT
270
The granularity of this measurement is
100 ms. A value of 0 ms indicates that
there hasn't been round-trip
communication with the server yet.
Buttons
Auto-refresh
: Check this box to refresh the Page automatically. Automatic refresh occurs every 3 seconds.
:
Click to refresh the Page immediately.
: Clears the counters for the selected server. The "Pending Requests" counter will not be cleared by this
operation.
4.11.10 Windows Platform RADIUS Server Configuration
Setup the RADIUS server and assign the client IP address to the Industrial Managed Switch. In this case, field in the default
IP Address of the Industrial Managed Switch with 192.168.0.100. And also make sure the shared
secret key
is as same as
the one you had set at the Industrial Managed Switch’s 802.1x system configuration –
12345678
at this case.
1.
Configure the IP Address of remote RADIUS server and secret key.
Figure 4-11-11:
RADIUS Server Configuration Screenshot