User’s Manual of IGS-20040MT
327
The interval between each loop protection PDU sent on each port. valid values
are 1 to 10 seconds.
Transmission Time
The period (in seconds) for which a port will be kept disabled in the event of a
loop is detected (and the port action shuts down the port). Valid values are 0 to
604800 seconds (7 days). A value of zero will keep a port disabled (until next
device restart).
Shutdown Time
Port Configuration
Object
Description
The switch port number of the port.
Port
Controls whether loop protection is enabled on this switch port.
Enable
Configures the action performed when a loop is detected on a port. Valid values
are
Shutdown Port
,
Shutdown Port and Log
or
Log Only
.
Action
Controls whether the port is actively generating loop protection PDU's, or
whether it is just passively looking for looped PDU's.
Tx Mode
Buttons
: Click to apply changes
:
Click to undo any changes made locally and revert to previously saved values.