User’s Manual of IGS-20040MT
removed from the active topology.
Control whether a port in the error-disabled state automatically will be enabled
after a certain time. If recovery is not enabled, ports have to be disabled and
re-enabled for normal STP operation. The condition is also cleared by a system
reboot.
Port Error Recovery
The time that has to pass before a port in the
error-disabled
state can be
enabled. Valid values are between 30 and 86400 seconds (24 hours).
Port Error Recovery
Timeout
The Industrial Managed Switch implements the Rapid Spanning Protocol as the default spanning
tree protocol. When selecting
“Compatibles”
mode, the system uses the RSTP (802.1w) to be
compatible and to co-work with another STP (802.1D)’s BPDU control packet.
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
4.7.3 Bridge Status
This Page provides a status overview for all STP bridge instances. The displayed table contains a row for each STP bridge
instance, where the column displays the following information. The Bridge Status screen in
Figure 4-7-5
appears.
Figure 4-7-5:
STP Bridge Status Page Screenshot
The Page includes the following fields:
Object
Description
The Bridge Instance. This is also a link to the STP Detailed Bridge Status.
MSTI
The Bridge ID of this Bridge instance.
Bridge ID
The Bridge ID of the currently elected root bridge.
Root ID
Root Port
The switch port currently assigned the
root
port role.
153