30
ATR 142 - User manual
8.5
Relating Timers to Alarms
It is possible to associate the alarms (relay or SSR outputs) to
the timers by parameters 23
aL. 1
and 31
aL. 2.
The table be-
low is showing the combined operation of alarms and Timers.
Selection
par. 23 or 31
Description
t.1.s.a.
Timer 1 Start Alarm
Alarm active as long as Timer 1 is in
Start mode (Timer active)
t.1.E.a.
Timer 1 End Alarm
Alarm active at elapsing of Timer1 until
any key is pressed. Option not available
for Dual sequential Timer and Dual
Timer Loop.
t.1.W.a.
Timer 1 Warning
Expiring
Alarm active for the last 5” of Timer1
t.2.s.a.
Timer 2 Start Alarm
Alarm active as long as Timer 2 is in
Start mode (Timer active)
t.2.e.a.
Timer 2 End Alarm
Alarm active at elapsing of Timer2 until
any key is pressed. Option not available
for Dual sequential Timer and Dual
Timer Loop.
t.2.w.e.
Timer 2 Warning
Expiring
Alarm active for the last 5” of Timer2
t.1.2.s.
Timer 1-2 Start Alarm
Alarm active as long as Timers 1 and 2
are in Start mode (Timers active)
t.1.2.e.
Timer 1-2 End Alarm
Alarm active at elapsing of Timers 1 and
2 until any key is pressed. Option not
available for Dual sequential Timer and
Dual Timer Loop.