  Replacement Parts List: 

Part 

Part Number 

LINX TDS Cartridges 

08-00033-B 

LINX Sediment Filters 

28-000509 

LINX Carbon Filters 

28-000506 

LINX TDS Cell Wrench 

19-000126 

Filter Housing Wrench 

19-000118 

0.25 gpm Flow Restrictor set 

07-000122 

0.15 gpm Flow Restrictor set 

07-000123 

Filter Housing o-ring 

28-000507 

LINX TDS Cartridge top o-ring 

28-00037-A 

LINX TDS Cartridge bottom o-ring 

28-00025-A 

LINX cell lid drivers 

19-000001-C 

Front Enclosure 

07-000008 

Front Lid Cover 

07-000012 

Back Lid Cover 

07-000013 

Drain Valve Body, Left (from rear) 

19-000309   

Drain Valve Body, Right (from rear) 

19-000310 

LED PCB 

07-000610 

Power cord 

19-000006 

Isolation Drain Valve Retrofit Kit 

07-050055 

   
 
 

 

LINX 140T Drinking Water Systems are manufactured by: 

 

Pionetics Corporation

 

151 Old County Road, Suite H 
San Carlos, CA    94070    USA 

866-611-8624 

Business Hours. 

: M-F 8:00 AM to 4:30 PM (PT) 

 
 

 

 

Contact Pionetics for service and replacement components

 

Содержание LINX 140T

Страница 1: ...l Software 20 067 Owner s Manual For service related questions call 866 611 8624 between 8 00 am and 4 30 pm Pacific time If you have problems at other times then turn off the feed water and unplug th...

Страница 2: ...ecting Feed Water TDS Level Pre Conditioning Procedure System Operation Dial A Taste Mineral Level Control Indicator Lights Section 5 Maintenance LINX TDS LINX Sediment and LINX Cartridges Filters Dra...

Страница 3: ...nstalled These systems are not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given super...

Страница 4: ...maximum TDS of 1000 ppm 20 grains of hardness 340 ppm hardness as CaCO3 pH 4 10 microbiologically safe Feed Water Pressure 20 80 psi 130 550 kPa Feed Water and Operating Temperature 33 100 F 1 40 C Re...

Страница 5: ...tain that you can reach the faucet under the sink to tighten it and connect the tubing Before you start your install the system 1 Buy an RO Faucet for your LINX System and slide the decorative plate o...

Страница 6: ...the right sized T Fitting or Angle Stop available it will be either a 1 4 3 8 or 1 2 inch outside diameter with a 1 4 inch T for the tubing that supplies the water to the LINX system 8 Determine wher...

Страница 7: ...to your cold water supply line Inline Shut off valve Heavy duty scissors Teflon plumber s tape Vaseline Plumber s Tape Tank Shut Off Valve This diagram illustrates plumbing connections using an air g...

Страница 8: ...dishwasher air gap Feed water is provided from the cold water supply under the sink via an Angle Stop on the cold water valve Do not use a saddle valve with puncturing needle because it will not prov...

Страница 9: ...hole in the tail piece so draining is not obstructed Installing the LINX system waste line to the drain below the horizontal arm of the P trap drain outlet where the P trap is full of water will lead...

Страница 10: ...d If you have a granite counter top you may want to hire someone to drill the hole for you 3 Locate where you want to put the LINX system and the storage tank under the sink ensuring a 110V Electrical...

Страница 11: ...round the filters and return the filters into their respective filter housings The Sediment Filter can be inserted into the housing in either direction but the Carbon Filter needs to be inserted with...

Страница 12: ...led 10 Locate the two LINX TDS cartridges see Figure 9 Then locate and lift out the two Lid Drivers from the exposed LINX unit see Figure 10 to identify these parts and location 11 Slide the mushroom...

Страница 13: ...ides the technician with a complete system diagnosis and IF service is needed walks the technician through the step by step service process If you would like to purchase an FSA please call Tech Suppor...

Страница 14: ...ed in the Front Panel Button Operation table below the left two lights flash three times if set for low TDS and the right two lights flash three times if set for high TDS The two buttons required for...

Страница 15: ...1000 High 0 15 gpm Yellow 1000 1500 High 0 15 gpm Yellow TDS Reduction may be less than 85 above 1000 ppm TDS feed Pre Conditioning LINX TDS Sediment and Carbon Cartridges Filters Whenever powered th...

Страница 16: ...ter is always available the LINX systems are designed for intermittent not continuous use To obtain the specified 85 TDS reduction the systems must be configured as described in the Specification sect...

Страница 17: ...urning the dial clockwise increases mineral content As the dial is turned the blue and red LEDs will light up for several seconds to indicate the mineral level selected None of the four LEDs will ligh...

Страница 18: ...and plumbing must be periodically inspected and cleaned to avoid drain line clogging with scale The high water recovery of LINX systems means that the waste water contains a very high concentration of...

Страница 19: ...ly depressurized Depressurize the system and try again open the faucet to drain all water Remove the LINX TDS cartridges from both the front and back cells The LINX TDS cartridges will come out with t...

Страница 20: ...ithin 4 seconds on the front circuit board until indicator light C blinks three times This informs the LINX system that new LINX TDS cartridges have been installed and resets the volume counter for th...

Страница 21: ...y If occurs again after re powering call Pionetics No Product Water Flow Indicator lights B C and D flashing Lid safety switch es not triggered Remedy Assure that both lid covers blue are in the prope...

Страница 22: ...00037 A LINX TDS Cartridge bottom o ring 28 00025 A LINX cell lid drivers 19 000001 C Front Enclosure 07 000008 Front Lid Cover 07 000012 Back Lid Cover 07 000013 Drain Valve Body Left from rear 19 00...

Страница 23: ...Consumer Install 12 16 2016 23...

Отзывы: