Pionetics LINX 140T Скачать руководство пользователя страница 14

Consumer Install 12.16.2016 

14

Section 4.    Operation   

 

 

 

 

The  LINX  140T  system  operations  are  automatic.    The  systems  employ  two  flow  sensors  to  measure  and 
control product  and waste  water  volumes  and  to  indicate  when  it  is  time  to  replace  filters  and/or  cartridges.   

The user only has to open and close the faucet to operate the systems

.    The two blue lid covers on top 

must be properly engaged to allow operation.    Be certain that the corresponding lid covers are in the correct 
positions (Figure 2). There is a FRONT lid cover and a BACK lid cover labeled on top of each lid.    Install the 
two lids as shown so that the labels read properly from the front of the system.                                                                                                     
 
                                                                                                                                                                                             

Figure 2

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selecting Feed Water TDS Level  

 

 

 

 

 

 

 

 

 

 

 

 

 

During  installation  the  LINX  140T  system  must  be  configured  for  low  or  high  feed  water  TDS  using  the  front  panel  buttons. 
Determine your feed water TDS (refer to your water utility annual report) to determine if it is less than or greater than 400 ppm 
(low or high).    All LINX systems are set at the factory for low TDS feed water which provides 3 gallons of drinking water at 70% 
recovery.    The high TDS setting provides 1.5 gallons at 55% recovery.    If the feed water is greater than 400 ppm, program for 
high TDS.    See the “Summary of Front Panel Operation” table in section 3.4 to change the feed water TDS setting.     
 
To determine whether the system is configured for low or high TDS feed water, repower it and check lights:    as indicated in the 
Front Panel Button Operation table below, the left two lights flash three times if set for low TDS, and the right two lights flash 
three times if set for high TDS.     
 
The two buttons required for set-up and maintenance are accessed by removing the blue front panel from the LINX 140T system.   
The two securing screws are located at the bottom.    To remove the front panel, push down on the top of the white portion of the 
enclosure, just behind the panel, and pull the panel forward.    This exposes the front panel PCB and filters.    The PCB has two 
black buttons

.    See the following table for operation of these two buttons. 

 
Front Panel Button Operation 

Operation 

Left Button 

Right Button 

 

Activate the LED-UV Filter 
(An optional component - not standard equipment) 

Press 2 times within 4 sec 

Lights A & B will flash three times 

 

Set-up system for operation on low TDS (<400 ppm) 

All systems are factory delivered set for low TDS* 

Press 4 times within 4 sec 

Lights A & B will flash three times 

--- 

Set-up system for operation on high TDS   
(400-1000 ppm) 

Press 5 times within 4 sec 

Lights C & D will flash three times 

--- 

Reset  LINX  100  Sediment  and  Carbon  filter  volume 
counter to zero 

--- 

Press 4 times within 4 sec 

(B light blinks 3 times) 

Reset LINX 100 TDS cartridge volume counter to zero 

--- 

Press 5 times within 4 sec 

(C light blinks 3 times) 

Initiate 90 minute conditioning for new LINX 100 TDS 
cartridges 

Press and hold   

(lights blink back and forth) 

Press and hold (at same time as 

left button) 

*To determine if system is set for low or high TDS, repower to observe the A,B or C,D flashing light signal. 
     

BACK

FRONT

Front of System

BACK

FRONT

Front of System

Содержание LINX 140T

Страница 1: ...l Software 20 067 Owner s Manual For service related questions call 866 611 8624 between 8 00 am and 4 30 pm Pacific time If you have problems at other times then turn off the feed water and unplug th...

Страница 2: ...ecting Feed Water TDS Level Pre Conditioning Procedure System Operation Dial A Taste Mineral Level Control Indicator Lights Section 5 Maintenance LINX TDS LINX Sediment and LINX Cartridges Filters Dra...

Страница 3: ...nstalled These systems are not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given super...

Страница 4: ...maximum TDS of 1000 ppm 20 grains of hardness 340 ppm hardness as CaCO3 pH 4 10 microbiologically safe Feed Water Pressure 20 80 psi 130 550 kPa Feed Water and Operating Temperature 33 100 F 1 40 C Re...

Страница 5: ...tain that you can reach the faucet under the sink to tighten it and connect the tubing Before you start your install the system 1 Buy an RO Faucet for your LINX System and slide the decorative plate o...

Страница 6: ...the right sized T Fitting or Angle Stop available it will be either a 1 4 3 8 or 1 2 inch outside diameter with a 1 4 inch T for the tubing that supplies the water to the LINX system 8 Determine wher...

Страница 7: ...to your cold water supply line Inline Shut off valve Heavy duty scissors Teflon plumber s tape Vaseline Plumber s Tape Tank Shut Off Valve This diagram illustrates plumbing connections using an air g...

Страница 8: ...dishwasher air gap Feed water is provided from the cold water supply under the sink via an Angle Stop on the cold water valve Do not use a saddle valve with puncturing needle because it will not prov...

Страница 9: ...hole in the tail piece so draining is not obstructed Installing the LINX system waste line to the drain below the horizontal arm of the P trap drain outlet where the P trap is full of water will lead...

Страница 10: ...d If you have a granite counter top you may want to hire someone to drill the hole for you 3 Locate where you want to put the LINX system and the storage tank under the sink ensuring a 110V Electrical...

Страница 11: ...round the filters and return the filters into their respective filter housings The Sediment Filter can be inserted into the housing in either direction but the Carbon Filter needs to be inserted with...

Страница 12: ...led 10 Locate the two LINX TDS cartridges see Figure 9 Then locate and lift out the two Lid Drivers from the exposed LINX unit see Figure 10 to identify these parts and location 11 Slide the mushroom...

Страница 13: ...ides the technician with a complete system diagnosis and IF service is needed walks the technician through the step by step service process If you would like to purchase an FSA please call Tech Suppor...

Страница 14: ...ed in the Front Panel Button Operation table below the left two lights flash three times if set for low TDS and the right two lights flash three times if set for high TDS The two buttons required for...

Страница 15: ...1000 High 0 15 gpm Yellow 1000 1500 High 0 15 gpm Yellow TDS Reduction may be less than 85 above 1000 ppm TDS feed Pre Conditioning LINX TDS Sediment and Carbon Cartridges Filters Whenever powered th...

Страница 16: ...ter is always available the LINX systems are designed for intermittent not continuous use To obtain the specified 85 TDS reduction the systems must be configured as described in the Specification sect...

Страница 17: ...urning the dial clockwise increases mineral content As the dial is turned the blue and red LEDs will light up for several seconds to indicate the mineral level selected None of the four LEDs will ligh...

Страница 18: ...and plumbing must be periodically inspected and cleaned to avoid drain line clogging with scale The high water recovery of LINX systems means that the waste water contains a very high concentration of...

Страница 19: ...ly depressurized Depressurize the system and try again open the faucet to drain all water Remove the LINX TDS cartridges from both the front and back cells The LINX TDS cartridges will come out with t...

Страница 20: ...ithin 4 seconds on the front circuit board until indicator light C blinks three times This informs the LINX system that new LINX TDS cartridges have been installed and resets the volume counter for th...

Страница 21: ...y If occurs again after re powering call Pionetics No Product Water Flow Indicator lights B C and D flashing Lid safety switch es not triggered Remedy Assure that both lid covers blue are in the prope...

Страница 22: ...00037 A LINX TDS Cartridge bottom o ring 28 00025 A LINX cell lid drivers 19 000001 C Front Enclosure 07 000008 Front Lid Cover 07 000012 Back Lid Cover 07 000013 Drain Valve Body Left from rear 19 00...

Страница 23: ...Consumer Install 12 16 2016 23...

Отзывы: