Consumer Install 12.16.2016
20
Re-pressurize with feed water and connect power to the LINX system. A,B or C,D lights will flash three times to indicate
whether the system is programmed for low or high TDS, then all four lights will flash right-left-right for 90 seconds during
which time water will flow from feed to drain to fill the LINX cells. During this period, open the faucet until water flows to
aid the purging process.
Remove the blue front panel from the unit. The two securing screws are located at the bottom. Press the white enclosure
plastic just behind the blue enclosure down and pull forward on the front panel.
Press the right button 5 times within 4 seconds on the front circuit board until indicator light C blinks three times. This
informs the LINX system that new LINX TDS cartridges have been installed (and resets the volume counter for these
cartridges).
Press and hold both buttons on the front circuit board until the indicator lights begin to move left to right to begin the
90-minute conditioning for new LINX TDS cartridges. Make sure the faucet is closed during conditioning.
Reattach the blue front panel to the LINX system.
Remove the lid covers and check for leaks. Replace the lid covers.
Open the tank valve.
5.5
Cleaners for Outer Enclosure
Use soap and water, rubbing alcohol (isopropanol), Formula 409, or other cleaners specified for plastic to clean the outer enclosure.
DO NOT use other solvents as they will scar the surface. If in doubt, test the cleaner on the bottom of the product first.