Operation
Sequence
Symptom
Check Item
Measures to be taken
Startup
Execution of startup
script
The following message is displayed on the FL
display: "FSCK-ERROR BOOT/USR"
Reinstall the OS (Installation leaving the user's data intact is also possible).
The following message is displayed on the FL
display: "FSCK-ERROR HOME"
Reinstall the OS (Installation leaving the user's data intact is also possible).
The following message is displayed on the FL
display: "FSCK-ERROR VAR"
Reinstall the OS (Installation leaving the user's data intact is also possible).
The following message is displayed on the FL
display: "POWER ON FSCK-ERROR"
Reinstall the OS (Installation leaving the user's data intact is also possible).
The following message is displayed on the FL
display: "NO BOARD ENCODER"
Check the connections.
The "Xilinx_STA" LED on the PCIB remains unlit during startup.
The "Encode_STA" LED on the PCIB remains lit during startup.
Check attachment of the PCI card to the DECB and MB.
It is suspected that the PCIB (DWP1080) is defective replace it.
It is suspected that the PCIB (DWP1080) is defective, replace it.
Misc.:
Check the power of the PCIB (DWP1080):
D2101: The LED for -12 V power supply remains unlit
D2102: The LED for +12 V power supply remains unlit
D2301: The LED for +5 V power supply remains unlit
The message "!!!!!!!!!!NO ENCODER BOARD ERROR AGAIN!!!!!!!!!!"
is displayed in the log file.
Check the LED for power supply on the PCIB (DWP1080).
It is suspected that the PCIB (DWP1080) is defective, replace it.
It is suspected that the PCIB (DWP1080) is defective, replace it.
It is suspected that the PCIB (DWP1080) is defective, replace it.
Reinstall the PCIB (DWP1080).
The following message is displayed on the FL
display: "NO BOARD ENCODER"
Check the connections.
The "Xilinx_STA" LED on the DECB remains unlit during startup.
The "Decode_STA" LED on the DECB remains lit during startup.
Check attachment of the PCI card to the DECB and MB.
It is suspected that the DECB (DWP1081) is defective,replace it.
It is suspected that the DECB (DWP1081) is defective,replace it.
Misc.:
Check the power supply for the DECB (DWP1081):
The LED (D1137) for +1.8 V power supply is unlit.
The message "!!!!!!!!!!NO DECODER BOARD ERROR AGAIN!!!!!!!!!!"
is displayed in the log file.
Check the LED for power supply on the DECB (DWP1081).
It is suspected that the DECB (DWP1081) is defective,replace it.
If it is suspected that ICP (IC1351) is broken, replace it.
Reinstall the DECB (DWP1081).
Starting application
Completion of
application startup
Even if the STB SW is pressed, the
message on the FL display remains
"000. . . ." and the unit does not start.
Check the connections:
The "Xilinx_STA" LED on the AVIB remains unlit during startup.
The "Encode_STA" LED on the AVIB remains lit during startup.
The "Xilinx_STA" LED on the PCIB remains unlit during startup.
The "Encode_STA" LED on the PCIB remains lit during startup.
Check the connections between the AVIB and PCIB.
Reconnect the 50-pin FFCs (DDD1226) that connect the AVIB (CN3001 and
CN3002) and PCIB (CN2103 and CN2104), or replace them.
Reconnect or replace the 4-pin cable (DKP3640) that connects the AVIB
(CN3301) and PCIB (CN2101).
If it is suspected that the AVIB (DWV1198) is defective, replace it.
If it is suspected that the AVIB (DWV1198) is defective, replace it.
If it is suspected that the AVIB (DWV1198) is defective, replace it.
If it is suspected that the AVIB (DWV1198) is defective, replace it.
Misc.: Check the positions of the jumper pins in DVD Drive 1 and
Drive 2.
Set the jumper pin of Drive 1 to MASTER and that of Drive 2 to SLAVE.