183
RS-232C Adjustment Mode
5.5.5 GET commands
What are GET commands?
• They are commands used for TXD output of adjustment data and the like from the plasma display’s built-in
microcomputer to a personal computer.
• Adjustment data, etc., is output in ASCII code.
(NOTE) Command names are given inside brackets < >.
• Data output format
(NOTE)
1) GET commands will be invalid if sets have not has not been assigned ID Nos.
2) GET commands will be invalid if a wildcard (*) is used in the ID No. when the command is transmitted.
1) <GPS> (GET POSITION DATA) – SCREEN adjustment data will be output as follows.
Order
Data
Size
Remarks
1
H.POSITION
3byte
2
V.POSITION
3byte
3
CLOCK
3byte
(NOTE)
4
PHASE
3byte
(NOTE)
5
V.SIZE
3byte
(NOTE) If the current input signal is a video signal or digital RGB signal, the adjustment data will be output as
dummy data.
2) <GWB> (GET W/B DATA) – PICTURE and WHITE BALANCE adjustment data will be output as follows.
Order
Data
Size
Remarks
1
CONTRAST
3byte
2
Dummy data
3byte
3
BRIGHT
3byte
4
Dummy data
3byte
5
COLOR
3byte
(NOTE)
6
Dummy data
3byte
7
TINT
3byte
(NOTE)
8
Dummy data
3byte
9
R HIGH
3byte
10
Dummy data
3byte
11
G HIGH
3byte
12
Dummy data
3byte
13
B HIGH
3byte
14
Dummy data
3byte
15
R LOW
3byte
16
Dummy data
3byte
17
G LOW
3byte
18
Dummy data
3byte
19
B LOW
3byte
20
Dummy data
3byte
21
H.ENHANCE (H.SHARP)
3byte
22
V.ENHANCE (V.SHARP)
3byte
(NOTE) If the current input signal is from a personal computer, the adjustment data will be output as dummy data.