PDP-5010FD
77
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Specifications for port monitoring
Port Name
SD/PD Indication
Active
RST2
ASIC power
(M-DCDC)
Shutdown occurs when the
signal is "L."
for 5 sec after PSW1 is ON.
or
for 2 sec while the unit is
ON.
RST3
AC power
AC_OFF when the signal is
"H."
Monitoring conditions
• Panel ON (RST4 = H and
PSW1 = L)
• While awaiting restoration
of RST2 (RST2 = L)
Operation
The SD timer starts when "RST2 = L" is detected under
monitoring conditions. If "RST3 = H," "M_SW_DET_B = H," or
"RST4 = L" is detected, or if a power-down or shutdown in the
module microcomputer system is not generated, the unit waits
for 30 mS. Then, if the SD timer continues to count for 2 sec
or more, a shutdown is determined, and a shutdown process
starts. A specific LED flash pattern (blue LED, 13 times)
starts. The next PON operation is valid, and the flag is cleared
upon the next power-on.
If RST2 is H, a restoration process starts according to the
latest power-on/-off status.
• Active STB (including SD/PD
statuses)
• Functional STB
• Panel ON
• (Areas other than North America)
While the main power switch is
set to OFF (M_SW_DET_B = H)
• (North America) While the main
power switch is set to OFF
(M_SW_DET_B = H)
• While awaiting restoration of AC
power (RST3 = H)
• While awaiting restoration of
RST2 (RST2 = L)
• While awaiting restoration of
RST4 (RST4 = L)
If "RST3 = H" (AC_OFF) is detected under the
monitoring conditions, a power-off process starts.
Monitoring of the RST3 port is continued, while
monitoring of other ports is interrupted.
Communication is controlled only by the IF
microcomputer. The port outputs are set as specified.
If the signal at the RST3 port continues to be H after
30 mS of waiting, monitoring is continued.
If RST3 is L, a restoration process starts according to
the latest power-on/-off status.
RST4
MAIN power
(RELAY)
Shutdown occurs if the
signal is "L."
for 5 sec after RELAY is
ON.
or
for 2 sec while the unit is
ON or in Functional STB.
• Functional STB
• Panel ON
• (Areas other than North America)
While the main power switch is
set to OFF (M_SW_DET_B = H)
• While awaiting restoration of
RST2 (RST2 = L)
• While awaiting restoration of
RST4 (RST4 = L)
The SD timer starts when "RST4 = L" (power-off of
devices in the functional STB system) is detected under
monitoring conditions.
The RST4 initialization process starts, and input
monitoring, communication setting, and output-terminal
setting are performed.
The RST4-SD timer starts. If either "RST3 = H" or
"M_SW_DET_B = H" is detected, or if a power-down or
shutdown in the module microcomputer system is not
generated, the unit waits for 30 mS. Then, if the SD
timer continues to count for 2 sec or more, a shutdown
is determined, and a shutdown process starts.
A specific LED flash pattern (blue LED, 13 times) starts.
The next PON operation is valid, and the flag is cleared
upon the next power-on.
If RST4 is H, a restoration process starts according to
the latest power-on/-off status.
Power supply and DC-DC converter
SW_REG
MAIN
POWER
SW
DC/DC Converter
MODULE_Ucom
Inverter
AND
AND
Overvoltage
Detection
RST4
RST3
PSW1
RST2
ACTIVE
AC shutdown
detection
Voltage
detection
Voltage
detection
DC_DC Converter
output control
PON/POFF
Command
Startup
Main ucom
Command
MAIN_UCOM
IF_UCOM
POWER SUPPLY Unit
DIGITAL ASSY
MAIN Assy
Circuit configuration
V+3.3V_D
V+3.3V_UCOM
V+5.1V
AC_DET
RELAY
PULL_U
V+12V
PULL_D
PULL_U
V+5V_USB
V+6.5V
PULL_D
PULL_U
V+5.1V
EMG_DDC
EMG_
USB
PULL_D
PULL_U
Содержание PDP-5010FD
Страница 19: ...PDP 5010FD 19 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 20: ...PDP 5010FD 20 1 2 3 4 1 2 3 4 C D F A B E 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Страница 22: ...PDP 5010FD 22 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL WIRING DIAGRAM 2 2 V 8V_AU V 3_3V_A V 3_3V_AU_D ...
Страница 23: ...PDP 5010FD 23 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 35: ...PDP 5010FD 35 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 167: ...PDP 5010FD 167 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 178: ...PDP 5010FD 178 1 2 3 4 1 2 3 4 C D F A B E 10 6 PANEL CHASSIS SECTION ...
Страница 182: ...PDP 5010FD 182 1 2 3 4 1 2 3 4 C D F A B E 10 8 PDP SERVICE ASSY 508F AWU1272 Exterior Section ...