PDP-5010FD
135
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Recovery flowchart (1-4)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1) / Recovery flowchart (1-3)]
RST MASK 03 (Green)
Display RST MASK 12 (Light blue). / [MKS S62]
Display RST MASK 10 (Pink). / [MKS S60]
Replacement of abnormal circuits or
re-replacement of the panel re
q
uired
N
o
Yes
Set VOL OFFSET to the current setting value minus 112. / [VOF
***]
Gradually decrease the VOL OFFSET value until disappear the
discharge (dead cell).
The VOL OFFSET value must be 117 or greater.
Current VOL OFFSET < 117?
[To the Main flowchart (2)]
Set VOL OFFSET to the current setting value plus 64. / [VOF
***]
Determine the current VOL OFFSET setting value as the final value.
Replacement of abnormal circuits or
re-replacement of the panel re
q
uired
N
o
Yes
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Replacement of abnormal circuits or
re-replacement of the panel re
q
uired
N
o
Yes
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Содержание PDP-5010FD
Страница 19: ...PDP 5010FD 19 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 20: ...PDP 5010FD 20 1 2 3 4 1 2 3 4 C D F A B E 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Страница 22: ...PDP 5010FD 22 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL WIRING DIAGRAM 2 2 V 8V_AU V 3_3V_A V 3_3V_AU_D ...
Страница 23: ...PDP 5010FD 23 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 35: ...PDP 5010FD 35 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 167: ...PDP 5010FD 167 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 178: ...PDP 5010FD 178 1 2 3 4 1 2 3 4 C D F A B E 10 6 PANEL CHASSIS SECTION ...
Страница 182: ...PDP 5010FD 182 1 2 3 4 1 2 3 4 C D F A B E 10 8 PDP SERVICE ASSY 508F AWU1272 Exterior Section ...