Repair
3A0441A
25
Fluid Pump
Removal
1.
Perform Pressure Relief Procedure, page 7.
2.
Flush material out of striper.
3.
Disconnect drain line from the pump (211).
4.
Remove connecting rod shield (205).
5.
Slowly cycle pump to move piston rod so that con-
necting rod pin is visible.
6.
Disconnect pressure sensor (209) from the pump
(211) by holding sensor in place with a wrench and
unscrewing the swivel fitting (216) with an additional
wrench.
7.
Remove retaining ring from connecting rod and slide
sleeve down revealing connecting rod pin.
8.
Remove hose fittings and drain valve (113).
9.
Remove siphon tube/hose assembly from fluid
pump by unscrewing suction nut with packing
adjustment tool.
NOTE: When siphon tube (135) is removed from
pump intake, be sure to catch ball cage, ball, ball
seat, and o-ring or they will fall to the floor. Keep
these pieces together in the same order.
10. Use wrench to unscrew two bolts (128) from front
cover assembly (the fluid pump will hang loosely).
11. Remove connecting rod pin out of connecting rod to
allow for removal of fluid pump from striper.
NOTICE
Do not turn the sensor. The cable will become damaged.
ti15398a
211
ti15395a
205
ti15394a
211
209
216
ti15397a
ti15400a
ti15401a
113
ti15399a
135
ti15396a
128
ti15423a
Содержание Brite Stripper 3000SP