BREAKDOWN DETECTION FLOW CHART
Sheet DP028
NO JIB MOVEMENT (UP AND / OR DOWN)
FROM THE PLATFORM (OR TURNTABLE) CONTROL PANEL
Folio 4/5
Maintain the control
activated and check for
12V voltage at terminals
410 (up) and 409 (down) of
the printed circuit
NO
YES
12V
OK
Replace the jib switch
SA7 (or SA6)
C043 (or
END
Repair wiring
END
Open the platform control
panel (or turntable) and check
the wiring of jib switch SA7 (or
SA6)
NO
YES
Wiring
OK
Check the electric continuity of
the switch contacts when closed
NO
YES
Continuity
OK
Repair the connection or replace the
electric wiring harness between the jib
switch SA7 (or SA6) on the printed circuit of
the turntable control panel
END
Replace the U1 module
NO
YES
The fault
persists
Replace the
printed circuit
See Fiche
END
END
Maintain the control
activated and check for
12V voltage at terminals
406 (up) and 405 (down) of
the printed circuit
Platform jib fault
Turntable jib fault
C
Содержание HA20PX
Страница 2: ......
Страница 4: ...1 Repair manual 2...
Страница 10: ...Repair Manual vi 15 CORRECTIVE MAINTENANCE PROCEDURES 177...
Страница 26: ...Repair Manual 20...
Страница 28: ...Repair Manual 22...
Страница 36: ...Repair Manual 30...
Страница 46: ...135 Repair manual 40...
Страница 47: ...Repair manual 135 41 7 SAFETY LOCATION...
Страница 48: ...135 Repair manual 42...
Страница 51: ...Repair manual 135 45 8 1 3 Positions of fuses 19 22 26 27 23 25 24 21 20...
Страница 64: ...135 Repair manual 58...
Страница 66: ...135 Repair manual 60...
Страница 74: ...Repair manual 68 12 7 2 Commom orange label 6...
Страница 76: ...Repair manual 70 12 7 4 Other common label 7814 393 7814 394 GPL 7814 306 a 13 15 17 14 16 24 18 75 77...
Страница 77: ...Repair manual 71 12 7 5 Model specific labels 12 7 5 1 HA20PX 12 7 5 2 HA26PX 19 7814 647 3 19 76...
Страница 82: ...135 Repair manual 76...
Страница 84: ......
Страница 86: ...PREVENTIVE MAINTENANCE SHEET...
Страница 88: ...PREVENTIVE MAINTENANCE SHEET...
Страница 98: ......
Страница 100: ......
Страница 104: ......
Страница 108: ......
Страница 110: ......
Страница 118: ......
Страница 128: ......
Страница 134: ......
Страница 140: ......
Страница 144: ......
Страница 152: ......
Страница 164: ...BREAKDOWN DETECTION FLOW CHART Folio 4 4 Sheet DP066 THE MOTOR DOES NOT START THE STARTER IS ACTIVATED...
Страница 180: ......
Страница 186: ......
Страница 188: ......
Страница 190: ......
Страница 192: ......
Страница 194: ......
Страница 196: ......
Страница 198: ......
Страница 200: ......
Страница 202: ......
Страница 204: ......
Страница 206: ......
Страница 208: ......
Страница 212: ......
Страница 214: ......
Страница 216: ...CORRECTIVE MAINTENANCE SHEET...
Страница 218: ......
Страница 220: ......
Страница 222: ......
Страница 224: ......
Страница 226: ......
Страница 228: ......
Страница 230: ......
Страница 234: ......
Страница 236: ......
Страница 238: ......
Страница 240: ......
Страница 246: ......
Страница 248: ...CORRECTIVE MAINTENANCE SHEET Folio 2 2 CHANGING THE HYDRAULIC PUMP Sheet C091 7 6 3 3 1 2 4 5...
Страница 250: ......
Страница 252: ......
Страница 254: ......
Страница 256: ......
Страница 258: ......
Страница 260: ...CORRECTIVE MAINTENANCE SHEET Folio 2 2 CHANGING THE SWING JOINT ASSEMBLY Sheet C100 7 4 Figure 1 3 2 3 1...
Страница 265: ...CORRECTIVE MAINTENANCE SHEET Folio 3 3 CHANGING THE SLEW RING Sheet C106 12 13 11...
Страница 266: ......
Страница 268: ......
Страница 270: ......
Страница 272: ......
Страница 274: ...CORRECTIVE MAINTENANCE SHEET Folio 2 2 CHANGING THE JIB CYLINDER Sheet C115 2 4 3 5 1...
Страница 276: ...CORRECTIVE MAINTENANCE SHEET Folio 2 2 CHANGING THE TURNTABLE ROTATION REDUCING GEAR Sheet C117 4 2 5 3 1...
Страница 278: ......
Страница 282: ...CORRECTIVE MAINTENANCE SHEET CHANGING THE COUNTERWEIGHTS Sheet C134...