Function description
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 45
6
Status
Downward movement
v > 0
6 mm
Foot switch
1
System-Init
0
OSSD
0
Protected field
Interrupted
Mute 1/2
0
Dynamic muting
Inactive
7
Status
Press is at bottom dead
centre
v = 0
BDC
Foot switch
1
System-Init
0
OSSD
0
Protected field
Interrupted
Mute 1/2
0
Dynamic muting
Inactive
8
Status
Upward movement
Advance measuring field is
cleared
v < 0
Foot switch
1
Generally, the press travels
up automatically, the oper-
ator can release the foot
switch.
System-Init
1
OSSD
1 or 0
Protected field
Free or interrupted
Mute 1/2
0 - > 1
Dynamic muting
Inactive
Continue with step 1