![Pilz PSENvip RL D P Set Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/pilz/psenvip-rl-d-p-set/psenvip-rl-d-p-set_operating-manual_1556622103.webp)
Technical details
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 103
Inputs on the receiver
Number
5
Galvanic isolation
No
Signal level at "0"
-3 V … +5 VDC
Signal level at "1"
+15 V … +30 VDC
Input current
Typ. 6 mA
Recognition time
Min. 100 ms
Outputs on the receiver
Number of positive-switching single-pole semicon-
ductor outputs
8
Galvanic isolation
No
Output current at "1"
Max. 0.25 A at 24 VDC
Permitted range
0 ... 0.32 A
Short circuit protection
Electronic
Min. pulse width at "0" signal (off time)
100 ms
Max. cable length with cable cross section 0.25 mm
2
150 m
OSSD/Mute in accordance with EN 61496-1, type 4
Signal level at "0"
0 VDC (-3 V ... 2 V in accordance with EN 61496)
Signal level at "1"
UB - 1 VDC (11 V ... 30 V in accordance with EN
61496)
Residual current at "0" signal
Max. 1 mA (<2 mA in accordance with EN 61496)
Duration of on and off time during self test
40 µs
Max. cable resistance for detection of shorts
between contacts
16 Ohm
Max. capacitive load
20 nF for R
L
> 48 ohms with rated voltage
Max. inductive load
0.5 H
Transmitter synchronisation
Max. capacitive load
500 nF
Environmental data
Protection type (EN 60529)
IP54
Ambient temperature
0
℃
… 50
℃
(EN 60068-2-14)
Storage temperature
-35
℃
… 70
℃
(EN 60068-2-1, EN 60068-2-2)
Climatic suitability
93 % rel. h. at 40 °C
(EN 60068-2-78)
Condensation
Not permitted
Vibration
Frequency range: 10 Hz … 55 Hz