Function description
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 19
The following overview shows the fundamentals of the whole system. The signals from the
PSENvip transmitter and receiver are explained in the sections below.
OSSD 1
OSSD 2
Mute 1
TRM_ON
TRM_SYNC
TRM_ON
TRM_SYNC
Programmable safety
system
PSS 4000
Incremental encoder
Mute 2
Pinch point
Up/
Down
Power Off
System-Init
Protected field mode
Acknowledge-
ment of reduced
protected field
Inputs
Outputs
PSENvip receiver
PSENvip transmitter
CNC controller
Protected field mode
Setup
Foot switch
E-STOP
E-STOP contactor
User program
Safety valve
Prefill valve
Fig.: Overview of overall system
INFORMATION
Some inputs and outputs on the receiver are also used for communication
with the safety system (see section entitled "Communication with the safety
system"). If communication is not required, protected field mode can also be
controlled directly via the CNC controller.