Technical details
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 102
11
Technical details
11.1
Technical details
Technical details
Function
Camera-based protection system
Application area
EN 61496-1,-2, prEN 12622, EN 61508
Detection zone
Length
0.1 m … 10 m
Height
Max. 20 mm
Width
44 mm
Reaction time
4 ms
Category
Type 4 in accordance with IEC 61496-1
Resolution of protected field
Object size
7 mm
Resolution of advance measuring field
Sheet thickness
2 mm
Required penetration depth
From side
1.6 mm
From top or bottom
1.6 mm
Transmitter's electrical data
Number of inputs
2
Supply voltage
24 VDC
Tolerance range
20 V … 30 VDC including residual ripple of max. ±
1.2 V
Current consumption
0.2 A at 24 VDC
Connection type
M12, 4-pin
Cable cross section
Min. 0.14 mm
Light source
High Power LED
Service life
50 000 hours
Diameter of illuminated target area
70 mm
Receiver's electrical data
Supply voltage
24 VDC
Tolerance range
20 V … 30 VDC including residual ripple of max. ±
1.2 V
Current consumption
Max. 2 A at 24 VDC
Connection type
2 x M12, 8-pin