4.11. Cooling System
The pump and the coolant tank, which are mounted in the machine base, are the basic elements of the cooling system. The coolant
pump conveys the coolant via hoses, valves and guide heads to the saw blade. The main cooling via the guide heads is
complemented by an additional cooling system. The coolant quantity is regulated with valves. The coolant cools down and lubricates
the saw blade and flushes away metal chips. The pump switches on and off when the saw blade drive is started or shut down. The
pump can be started during the machine cleaning and also when the saw blade or the hydraulic unit is off. Activate the machine
cleaning menu - chips conveyor and manually start the coolant pump.
When handling coolants, risks linked to hazardous substances cannot be avoided. Observe the manufacturer's and/or
your company's instructions and recommendations referring to safe coolant handling.
If you fill too much coolant, an overflow resulting in spilling the coolant under the saw may occur.
SUPPLY HOSE
VALVE
MESH
COOLANT TANK
PUMP
ADDITIONAL COOLING
SPRAY GUN