3.1.1 DIRECT INSTALLATION IN THE LINE (Fig. 5)
When the relief valve is fitted directly in the line that is, without the interposition of an on/off valve, we recommend
proceeding as follows:
1) ensure that the downstream on/off valve V2 and the bleed cock 6 are closed;
2) increase the pressure in the downstream section to the value at which intervention should occur by connecting
a controlled auxiliary pressure to the cock 6 and stabilise it at the desired value;
3)check intervention of the relief valve and adjust it if necessary by turning the internal adjustment ring 14
appropriately (clockwise to increase the set-point, anticlockwise to reduce it).
3.1.2 INSTALLATION WITH ON/OFF VALVE (Fig. 6)
1)Close the on/off valve 16;
2)connect a controlled auxiliary pressure to the take-off 17 and increase it slowly to the envisaged intervention
value;
3)check the intervention of the relief valve and adjust it if necessary by turning the internal adjustment ring 14
appropriately (clockwise to increase the set-point, anticlockwise to reduce it).
Fig. 6
Fig. 5
Содержание NORVAL
Страница 2: ...TECHNICAL MANUAL MT044 2 Inlet pressure Outlet pressure NORVAL Issue February 2003 ...
Страница 4: ...4 ...
Страница 8: ...8 ...
Страница 10: ...TECHNICAL MANUAL MT044 10 5 Pe 4 1 3 2 74 Pa Fig 1 ...
Страница 36: ...TECHNICAL MANUAL MT044 36 7 2 NORVAL REGULATOR MAINTENANCE PROCEDURE Fig 17 ...
Страница 39: ...TECHNICAL MANUAL MT044 39 7 3 NORVAL REGULATOR I N MAINTENANCE PROCEDURE Fig 18 ...
Страница 43: ...TECHNICAL MANUAL MT044 43 7 4 MAINTENANCE PROCEDURE FOR THE NORVAL REGULATOR I N ER Fig 19 ...
Страница 50: ...TECHNICAL MANUAL MT044 50 9 0 LIST OF RECOMMENDED SPARE PARTS ...
Страница 51: ...TECHNICAL MANUAL MT044 51 NORVAL pression regulator ...
Страница 58: ...TECHNICAL MANUAL MT044 58 NOTES ...
Страница 59: ...TECHNICAL MANUAL MT044 Ordering Information Part No PFN375DN50 40 PFN375DN50 45 ...