GOVERNORS NOR
TH AMERICA
LOW PRESSURE GAS REGULATOR
|
DESCRIPTION AND OPERATION
|
REV. A
US
Operation, maintenance and warning manual
4.3.2 - DUAL CUT VERSION OPERATION
The Dual Cut version stipulates that the regulator:
• upstream (A) adjusts the pressure to 1.7 PSIG;
• downstream (B) adjusts the pressure to the required outlet pressure.
If the downstream regulator (B) fails, the upstream regulator (A) maintains the outlet pressure below the CSA limit of 2
PSIG.
In the event of failure of the downstream regulator (B), the upstream regulator (A) should limit the down-
stream outlet pressure without undergoing set point changes.
A
B
U
pstream
(
inlet
)
pressUre
D
ownstream
(
oUtlet
)
pressUre
p
ressUre
1.7 psiG
Fig. 4.7. Dual Cut version operation